I N S T A L L A T I O N P R O C E D U R E S
66
FOX615
Installation
3.7.3
Alarm interfaces
3.7.3.1
Interfaces and connectors
The FOX alarm interfaces are physically all implemented on the FAMO1 or
FAMO1-F
unit. The individual input and output interfaces are arranged in
groups with a connector per group.
Figure 37: FAMO1 and FAMO1-F
alarm interfaces
All alarm interfaces use Molex connectors. To avoid wrong connections con-
nectors with different number of contacts are implemented for each interface
type.
For all connections between FOX equipment cables are provided. Connector
sets are provided for interfaces which are user configurable (alarm inter-
faces). The sets contain the Molex connector frame and crimp terminals.
Figure 38: Molex connector frames and crimp terminals
Legend:
1
Molex connector frame
2
Mini-Fit HCS
TM
crimp terminal (AWG 18 … AWG 24)
3
Wire (AWG 18 … 24)
S
Inserting the Mini-Fit HCS
TM
crimp terminal into the connector
frame
P
Plugging the connector frame into the FAMO1 or FAMO1-F
interface
The crimp terminals (2) accept wires as follows:
F3 : Alarm inputs
1 -4
F4: Alarm inputs
5-8
F5: Alarm inputs
9-12
F2: Alarm output
1-2
50
moving fans
refer to handbook
F2 F3 F4 F5
fan 48 VDC 19" 1U
37970003
R2A
2111743473
2011 W44
1
2
3
P
S