7.2 Protective stop
Introduction
The FlexLoader Standard Safety handles protective stop and manual operation of
dangerous equipment. The protective stop mode ensures safe stop of equipment
upon cell entry and prevents the equipment from being started while the cell is
accessible.
Standard operation
The example below shows a typical operator panel made by an integrator, handling
entry request, door reset and restart. Only emergency stop, emergency stop reset
and door reset key switch interacts with the safety center.
xx1900000172
Description
Pos.
Emergency stop
A
Start button (integrator dependent)
B
Entry request button
C
Key switch
D
Emergency stop reset button (if master)
E
Protective stop
Request entry to the robot cell through routines provided by the robot program.
DANGER
When entering the cell, the operator must bring the key that is used to confirm
the protection door. This is to prevent somebody else from confirming and
restarting FlexLoader Standard Safety Center when the operator is inside the
cell. There may only be one key for the entire cell.
Take the key (D) and carry out the work in the cell.
Continues on next page
46
Application manual - FlexLoader Standard Safety Center
3HAC051769-001 Revision: E
© Copyright 2014-2020 ABB. All rights reserved.
7 Operation
7.2 Protective stop
Summary of Contents for FlexLoader
Page 1: ...ROBOTICS Application manual FlexLoader Standard Safety Center ...
Page 6: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 28: ...This page is intentionally left blank ...
Page 30: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 66: ......
Page 67: ......