Planning the electrical installation
56
3ADW000462R0401 DCS880 Hardware manual e d
Cooling fans
Fan assignment for DCS880
b = Bridge type
d = Rated AC voltage
Fan cable sizes and tightening torque connected at the fan terminals
Fan terminals are X52 for H4, X2 for H5/H6 and U1, V1, W1 for H7/H8.
d = Rated AC voltage
Converter type
Size
Configuration
Fan type
Airflow built in [m³/h]
DCS880-S0b-0045-04/05 ...
DCS880-S0b-00100-04/05
H1
1
1 x 3110UL
57
DCS880-S0b-0135-04/05 ...
DCS880-S0b-0300-04/05
H2
2
2 x AFB122
170
DCS880-S01-0290-06
DCS880-S02-0320-06
DCS880-S0b-0315-04/05 ...
DCS880-S0b-0450-04/05
H3
DCS880-S0b-0470-04/05 ...
DCS880-S0b-0520-04/05
3
2 x 3110UL
2 x AFB122
255
DCS880-S01-0590-06
DCS880-S02-0650-06
DCS880-S0b-0610-04/05 ...
DCS880-S0b-0820-04/05
H4
4
1 x W2E200
230 V; 1
388
DCS880-S0b-0900-04/05 ...
DCS880-S0b-1000-04/05
1 x W2E250
230 V; 1
425
DCS880-S0b-1190-04/05
H5
5
R2E250-RB
230 V; 1
918
DCS880-S0b-0900-0d ...
DCS880-S0b-2000-0d
H6
850
DCS880-S0b-1900-0d ...
DCS880-S0b-3000-0d
H7
6
GR28C-2DK
400 V / 500 V @ 50 Hz
or
460 V @ 60 Hz
1700
DCS880-S0b-2050-dd ...
DCS880-S0b-5200-dd
H8
7
GR35C-2DD
400 V @ 50 Hz or
460 V @ 60 Hz
4500
Converter type
Flexible cable
Solid cable
max [mm²]
torque [Nm]
max [mm²]
torque [Nm]
DCS880-S0x-0610-dd ...
DCS880-S0x-1000-dd
0.5 … 1.5
0.5 … 0.6
0.5 … 1.0
0.5 … 0.6
DCS880-S0x-1190-dd …
DCS880-S0x-2000-dd
0.5 … 1.5
0.5 … 0.6
0.5 … 1.0
0.5 … 0.6
DCS880-S0x-1900-dd ...
DCS880-S0x-3000-dd
0.5 … 1.5
Push in
0.5 … 1.5
Push in
DCS880-S0x-2050-dd ...
DCS880-S0x-5200-dd
0.5 … 1.5
0.6 … 0.8
0.5 … 1.5
0.6 … 0.8