Accessories
151
3ADW000462R0401 DCS880 Hardware manual e d
Dimensions of fuse holders
OFAX xx xxx170H 3006 (IP00)
Line reactors IEC
Line reactors type ND01 ... ND17 (u
k
= 1 %)
Line reactors of Types ND01 ... ND17 are sized to the unit‘s nominal current and frequency (50 / 60
Hz). These line reactors with a u
k
of 1 % are designed for use in industrial environment (minimum
requirements). They have low inductive voltage drop, but deep commutation notches.
Line reactors ND01 ... ND06 are equipped with cables. The larger ones ND07 ... ND17 are equipped
with busbars. When connecting them to other components, please consider relevant standards in
case the busbar materials are different.
Attention:
Don't use reactor terminals as cable or busbar support!
not used for DCS880
Fuse holder
H x W x D [mm]
Protection
OFAX 00 S3L
148 x 112 x 111
IP20
OFAX 1 S3
250 x 174 x 123
IP20
OFAX 2 S3
250 x 214 x 133
IP20
OFAX 3 S3
265 x 246 x 160
IP20
Line reactor
L
IRMS
Ipeak
Rated voltage Weight
Power losses
Recommended for
(uk = 1 %)
[
H]
[A]
[A]
[UN]
[kg]
Fe [W] Cu [W]
armature converter
ND01
512
18
27
500
2.0
5
16
DCS...-0025
ND02
250 37
68
500
3.0
7
22
DCS...-0050
ND03
300 37
68
600
3.8
9
20
(DCS...-0050)
ND04
168
55
82
500
5.8
10
33
DCS...-0075
ND05
135
82
122
600
6.4
5
30
(DCS...-0100)
ND06
90
102
153
500
7.6
7
41
DCS...-0140
ND07
50
184
275
500
12.6
45
90
DCS...-0260
ND08
56.3
196
294
600
12.8
45
130
DCS...-0320
ND09
37.5
245
367
500
16.0
50
140
DCS...-0350
ND10
25.0
367
551
500
22.2
80
185
DCS...-0520
ND11
33.8
326
490
600
22.6
80
185
(DCS...-0450)
ND12
18.8
490
734
500
36.0
95
290
DCS...-0680
ND13
18.2
698
1047
690
46.8
170
160
DCS...-0900
ND14
9.9
930
1395
500
46.6
100
300
DCS...-1190 / 1200
ND15
10.9
1163
1744
690
84.0
190
680
DCS...-1500
ND16
6.1
1510
2264
500
81.2
210
650
DCS...-2000
ND17
4.0
1800
2700
800
86.0
250
700
DCS...-2500
OFAX 2 S3
H
W
D
M10
110
A
A
M8
27
205
180
64
77
M8
A-A
60
85
Ø
9
M10
40
170H3006_a.dsf