259
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
88.31 AnybusModType (last connected serial communication module)
Internally used memory for the last attached serial communication module. This value should only be written
to by:
−
the DCS550 firmware and
−
parameter download
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
65535
0
-
Group 90: Receiving data sets addresses
Addresses for the received data transmitted from the overriding control to the drive.
The format is xxyy, with: xx = group and yy = index.
90.01 DsetXVal1 (data set X value 1)
Data set 1 value 1 (interval: 3 ms).
Default setting of 701 equals MainCtrlWord (7.01).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
701
-
90.02 DsetXVal2 (data set X value 2)
Data set 1 value 2 (interval: 3 ms).
Default setting of 2301 equals SpeedRef (23.01).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
2301
-
90.03 DsetXVal3 (data set X value 3)
Data set 1 value 3 (interval: 3 ms).
Default setting of 2501 equals TorqRefA (25.01).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
2501
-
90.04 DsetXplus2Val1 (data set X+2 value 1)
Data set 3 value 1 (interval: 3 ms).
Default setting of 702 equals AuxCtrlWord (7.02).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
702
-
90.05 DsetXplus2Val2 (data set X+2 value 2)
Data set 3 value 2 (interval: 3 ms).
Default setting of 703 equals AuxCtrlWord2 (7.03).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
703
-
90.06 DsetXplus2Val3 (data set X+2 value 3)
Data set 3 value 3 (interval: 3 ms).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
0
-
90.07 DsetXplus4Val1 (data set X+4 value 1)
Data set 5 value 1 (interval: 3 ms).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
0
-
90.08 DsetXplus4Val2 (data set X+4 value 2)
Data set 5 value 2 (interval: 3 ms).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
0
-
90.09 DsetXplus4Val3 (data set X+4 value 3)
Data set 5 value 3 (interval: 3 ms).
Data set address = Ch0 DsetBaseAddr (70.24) + 4.
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
0
-
e.g. DWL
Group
Data words
Overriding control
90
Address
assignment
SDCS-CON-F
Serial communication via
slot 1 of SDCS-CON-F
1
...
10
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...