258
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
86.13 Block13Out (block 13 output)
The value of function block 13 output [Block1Output (84.81)] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals SpeedRef (23.01)].
The format is -xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1
Type: I
Volatile:
N
-9999
9999
0
-
86.14 Block14Out (block 14 output)
The value of function block 14 output [Block1Output (84.87)] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals SpeedRef (23.01)].
The format is -xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1
Type: I
Volatile:
N
-9999
9999
0
-
86.15 Block15Out (block 15 output)
The value of function block 15 output [Block1Output (84.93)] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals SpeedRef (23.01)].
The format is -xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1
Type: I
Volatile:
N
-9999
9999
0
-
86.16 Block16Out (block 16 output)
The value of function block 16 output [Block16Output (84.99)] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals SpeedRef (23.01)].
The format is -xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1
Type: I
Volatile:
N
-9999
9999
0
-
Group 88: Internal
This parameter group contains internal variables and should not be changed by the user
88.01 - 88.24 Reserved
88.25 M1TachMaxSpeed (maximum tacho speed)
Internally used maximum tacho speed. This value is depending on the analog tacho output voltage - e.g. 60 V
at 1000 rpm - and the maximum speed of the drive system - which is the maximum of SpeedScaleAct (2.29),
M1OvrSpeed (30.16) and M1BaseSpeed (99.04).
This value should only be written to by:
−
tacho fine tuning via ServiceMode (99.06) = SpdFbAssist,
−
via M1TachVolt1000 (50.13),
−
TachoAdjust block in AP and
−
parameter download
Internally limited from:
rpm
to
rpm
20000
32767
*
)
29
.
2
(
20000
32767
*
)
29
.
2
(
−
Int. Scaling: (2.29)
Type: SI
Volatile:
N
0
10000
0
rp
m
88.26 Reserved
88.27 M1TachoTune (tacho tuning factor)
Internally used tacho fine tuning factor. This value should only be written to by:
−
tacho fine tuning via ServiceMode (99.06) = SpdFbAssist,
−
TachoAdjust block in AP and
−
parameter download
Int. Scaling: 1000 == 1
Type: I
Volatile:
N
0
.3
3
1
-
88.28 Reserved
88.29 M1TachoGain (tacho tuning gain)
Internally used tacho gain tuning. This value should only be written to by:
−
tacho gain tuning via ServiceMode (99.06) = SpdFbAssist,
−
M1TachoVolt1000 (50.13) and
−
parameter download
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
15
15
-
88.30 Reserved
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...