165
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
5.05 AI3 Val (analog input 3 value)
Measured actual voltage at analog input 3. The integer scaling may differ, depending on the connected
hardware and jumper settings.
Int. Scaling: 1000 == 1 V Type: SI
Volatile:
Y
-
-
-
V
5.06 AI4 Val (analog input 4 value)
Measured actual voltage at analog input 4. The integer scaling may differ, depending on the connected
hardware and jumper settings.
Int. Scaling: 1000 == 1 V Type: SI
Volatile:
Y
-
-
-
V
5.07 AI5 Val (analog input 5 value)
Measured actual voltage at analog input 5. The integer scaling may differ, depending on the connected
hardware and DIP-switch settings.
Available only with RAIO extension module see AIO ExtModule (98.06).
Int. Scaling: 1000 == 1 V Type: SI
Volatile:
Y
-
-
-
V
5.08 AI6 Val (analog input 6 value)
Measured actual voltage at analog input 6. The integer scaling may differ, depending on the connected
hardware and DIP-switch settings.
Available only with RAIO extension module see AIO ExtModule (98.06).
Int. Scaling: 1000 == 1 V Type: SI
Volatile:
Y
-
-
-
V
5.09 - 5.10 Unused
5.11 AO1 Val (analog output 1 value)
Measured actual voltage at analog output 1.
Int. Scaling: 1000 == 1 V Type: SI
Volatile:
Y
-
-
-
V
5.12 AO2 Val (analog output 2 value)
Measured actual voltage at analog output 2.
Int. Scaling: 1000 == 1 V Type: SI
Volatile:
Y
-
-
-
V
5.13 - 5.14 Unused
5.15 AI1 ValScaled (analog input 1 scaled value)
Internally scaled value of analog input 1. Depending on setting of AI1HighVal (13.01) and AI1LowVal (13.02).
Example:
Setting of AI1HighVal (13.01) = AI1LowVal (13.02) = 4,000 mV gives a value of 250 % when AI1 = 10 V.
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
5.16 AI2 ValScaled (analog input 2 scaled value)
Internally scaled value of analog input 2. Depending on setting of AI2HighVal (13.05) and AI2LowVal (13.06).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
5.17 AI3 ValScaled (analog input 3 scaled value)
Internally scaled value of analog input 3. Depending on setting of AI3HighVal (13.09) and AI3LowVal (13.10).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
5.18 AI4 ValScaled (analog input 4 scaled value)
Internally scaled value of analog input 4. Depending on setting of AI4HighVal (13.13) and AI4LowVal (13.14).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
5.19 AI5 ValScaled (analog input 5 scaled value)
Internally scaled value of analog input 5. Depending on setting of AI5HighVal (13.21) and AI5LowVal (13.22).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
5.20 AI6 ValScaled (analog input 6 scaled value)
Internally scaled value of analog input 6. Depending on setting of AI6HighVal (13.25) and AI6LowVal (13.26).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
Group 6: Drive logic signals
6.01 SystemTime (converter system time)
Shows the time of the converter in minutes. The system time can be either set by means of SetSystemTime
(16.11) or via the DCS Control Panel.
Int. Scaling: 1 == 1 min
Type: I
Volatile:
Y
-
-
-
m
in
6.02 Unused
6.03 CurCtrlStat1 (1
st
current controller status)
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...