Wall mounted
Max. load (emergency stop)
Endurance load (in operation)
Force
±2860 N
±1478 N
Force xy
±963 N
±288 N
Force z
±2741 Nm
±1068 Nm
Torque xy
±863 Nm
±352 Nm
Torque z
Suspended
Max. load (emergency stop)
Endurance load (in operation)
Force
±2186 N
±821 N
Force xy
1547 N±1000 N
428 N±1000 N
Force z
±2392 Nm
±814 Nm
Torque xy
±583 Nm
±236 Nm
Torque z
Requirements, foundation
The table shows the requirements for the foundation where the weight of the
installed robot is included:
Note
Value
Requirement
Flat foundations give better repeatability of
the resolver calibration compared to original
settings on delivery from ABB.
0.1/500 mm
Flatness of foundation
surface
The value for levelness aims at the circum-
stance of the anchoring points in the robot
base.
In order to compensate for an uneven sur-
face, the robot can be recalibrated during in-
stallation. If resolver/encoder calibration is
changed this will influence the absolute ac-
curacy.
The value is recommended for optimal per-
formance.
22 Hz
Note
It may affect the ma-
nipulator lifetime to
have a lower reson-
ance frequency than
recommended.
Minimum resonance
frequency
Due to foundation stiffness, consider robot
mass including equipment.
i
For information about compensating for
foundation flexibility, see the description of
Motion Process Mode
in the manual that de-
scribes the controller software option, see
.
150 MPa
Minimum foundation
material yield strength
i
The minimum resonance frequency given should be interpreted as the frequency of the robot
mass/inertia, robot assumed stiff, when a foundation translational/torsional elasticity is added, i.e.,
the stiffness of the pedestal where the robot is mounted. The minimum resonance frequency should
not be interpreted as the resonance frequency of the building, floor etc. For example, if the equivalent
mass of the floor is very high, it will not affect robot movement, even if the frequency is well below
the stated frequency. The robot should be mounted as rigid as possibly to the floor.
Disturbances from other machinery will affect the robot and the tool accuracy. The robot has
resonance frequencies in the region 10 – 20 Hz and disturbances in this region will be amplified,
although somewhat damped by the servo control. This might be a problem, depending on the
requirements from the applications. If this is a problem, the robot needs to be isolated from the
environment.
Continues on next page
14
Product specification - CRB 1300
3HAC083113-001 Revision: C
© Copyright 2022-2023 ABB. All rights reserved.
1 Description
1.1.3.1 Technical data
Continued
Summary of Contents for CRB 1300
Page 1: ...ROBOTICS Product specification CRB 1300...
Page 6: ...This page is intentionally left blank...
Page 104: ...This page is intentionally left blank...
Page 112: ...This page is intentionally left blank...
Page 114: ...This page is intentionally left blank...
Page 116: ......
Page 117: ......