However, SafeMove may generate other warning messages anytime during the
Axis Calibration routine. When a warning message is displayed, tap
Acknowledge
to confirm the unsynchronized state and continue Axis Calibration procedure.
CAUTION
SafeMove must be synchronized after the calibration is completed.
After calibration
Note
Action
xx1600002102
Check the o-ring on the fixed calibration pin.
Replace if damaged or missing.
1
Reinstall the protective cover on the fixed calibra-
tion pin on each axis, directly after the axis has
been calibrated.
Replace the cover with new spare part, if missing
or damaged.
2
O-ring on calibration pin:
3HAC061327-022
O-ring on calibration pin:
3HAC061327-011
Calibration pin cover, 10 mm:
3HAC056253-003
Calibration pin cover, 14 mm:
3HAC056253-002
xx1500000952
Reinstall the protective plug and sealing in the
bushing on each axis, directly after the axis has
been calibrated. Ensure that the sealing is not
damaged.
Replace the plug and the sealing with new spare
part, if missing or damaged.
3
Protective plug for 10-mm bushing:
3HAC053237-003.
Protective plug for 12-mm bushing:
3HAC053237-002.
See
Calibrating with Wrist Optimiz-
If the standard calibration data for axes 4, 5 or 6
should be updated with wrist optimization, run the
calibration routine
Wrist Optimization
.
4
Product manual - CRB 1300
683
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
6 Calibration
6.4.4 Axis Calibration - Running the calibration procedure
Continued
Summary of Contents for CRB 1300
Page 1: ...ROBOTICS Product manual CRB 1300 ...
Page 50: ...This page is intentionally left blank ...
Page 662: ...This page is intentionally left blank ...
Page 690: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 725: ......