Loosening the process hub
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001538
Remove the screws and carefully open the cover.
CAUTION
There is cabling attached to the cover. The cover
cannot be removed completely.
2
Loosening the cables in the tubular
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001530
Cut the cable straps.
2
xx2000001531
Remove the connector plates.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
3
Continues on next page
Product manual - CRB 1300
531
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.