Note
Action
xx2000001545
Snap loose and remove the male head of the
connectors from the connector plate.
5
Separating the cable package from the housing
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001546
Remove the axis-4 cable protector.
2
Pulling out the cable package
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Wrap the connectors with the masking tape.
2
xx2000001662
Pull the cable package out to the lower arm sup-
port.
3
Continues on next page
Product manual - CRB 1300
433
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the tubular and tilt unit