Reconnecting the axis-2 and -3 motor connectors
Note
Action
xx2000001551
Insert the male header of the motor connectors
to the connector plate.
1
xx2000001549
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
xx2000001550
Reconnect the connectors.
•
FB2
•
MP2
•
FB3
•
MP3
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate to the lower arm.
4
Tightening torque: 2.6 Nm
xx2000001548
Continues on next page
366
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair