Removing the base covers
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001642
Valid for cabling with rear interface
Remove the base bottom cover together with the
base adapter.
2
Removing the axis-1 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
WARNING
When separating the motor from the gearbox,
there may be pressure present in the gearbox,
causing lubricant to spray from the opening. Be-
fore proceeding, please read the safety informa-
tion in the section
.
2
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
3
xx2000001643
Access the screws and washers securing the axis-
1 motor from the base bottom.
4
Continues on next page
268
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Summary of Contents for CRB 1300
Page 1: ...ROBOTICS Product manual CRB 1300 ...
Page 50: ...This page is intentionally left blank ...
Page 662: ...This page is intentionally left blank ...
Page 690: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 725: ......