Note
Action
Arrange the connectors as follows (facing the
SMB side):
•
Right of the connector plate:
- SMB.J1
- SMB.J2
- R2.MP1 on axis-1 motor
- R2.FB1 on axis-1 motor
•
Left of the connector plate:
- R2.SMB
- R2.MP1 on main cable package
- R2.FB1 on main cable package
5
Reconnecting the axis-1 motor connectors
Note
Action
xx2000001561
Insert the male header of the motor connectors
to the connector plate.
1
xx2000001560
Reconnect the connectors.
•
FB1
•
MP1
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
Product manual - CRB 1300
231
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued