Pulling out the cable package
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001564
Remove the axis-1 connector plate.
2
Wrap the connectors with the masking tape.
3
xx2000001563
Pull out the cable package in the direction as
shown in the figure.
Note
Slip out the cable protectors while pulling out the
cable package.
4
Slip out the cable protectors.
5
Refitting the cable package
Use these procedures to refit the cable package.
Securing the cable package in the base
Note
Action
Wrap the connectors with the masking tape.
1
Continues on next page
Product manual - CRB 1300
229
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued
Summary of Contents for CRB 1300
Page 1: ...ROBOTICS Product manual CRB 1300 ...
Page 50: ...This page is intentionally left blank ...
Page 662: ...This page is intentionally left blank ...
Page 690: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 725: ......