Note
Action
xx2000001573
Valid for cabling with bottom interface (option
3309-1)
Remove the base rear cover.
2
xx2000001574
Disconnect the earth cable.
3
Disconnecting the brake release connector
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 49
2
Cut the cable strap.
3
xx2100001480
Disconnect the connector.
•
R2.BRU
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
4
Continues on next page
228
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued