Accessories
126
Power Panel FT50 User's manual V1.19
Model number
5CASD3.
0030-00
5CASD3.
0050-00
5CASD3.
0100-00
5CASD3.
0150-00
5CASD3.
0200-00
5CASD3.
0300-00
5CASD3.
0500-00
5CASD3.
1000-00
General information
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
1)
EAC
Yes
Cable construction
Wire cross section
4x 2x 26/7 AWG
4x 2x 23/1 AWG
Properties
Flame-retardant, halogen-free, lead-free
Outer jacket
Material
Polyurethane (PUR)
Color
Yellow, RAL 1021
Labeling
HARTING INDUSTRIAL CABLE S/FTP CAT 6A PUR 4x2xAWG26/7
HARTING INDUSTRIAL INSTALLATION
CABLE S/FTP CAT 7 PUR 4x2xAWG23/1
Lines
Wire insulation
Polyethylene (PE)
Wire colors
Green/White-green, orange/white-orange, blue/white-blue, brown/white-brown
Shield
Aluminum foil and braided wire shield composed of tinned copper wires
Type
Bare copper strand, 4x 2x 26/7 AWG
Bare copper strand, 4x 2x 23/1 AWG
Connector
Type
2x RJ45, male
Mating cycles
Min. 750
Contacts
8
Electrical properties
2)
Operating voltage
≤100 V
≤125 V
Conductor resistance
≤290 Ω/km
≤75 Ω/km
Wave impedance
100 ±5 Ω (at 100 MHz)
Transfer properties
Category 6A / Class EA up to 500 MHz per ISO/IEC
11801 (EN 50173-1), ISO/IEC 24702 (EN 50173-3)
Category 7 / Class F up to 600 MHz
per ISO/IEC 11801 (EN 50173-1),
ISO/IEC 24702 (EN 50173-3)
Insulation resistance
≥500 MΩ/km
≥5 GΩ/km
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Flame-retardant
IEC 60332-1-2
Oil and hydrolysis resistance
EN 60811-2-1 (90°C / 7x24 h)
Degree of protection per EN 60529
Cables
IP20
RJ45 connector
IP20, only when properly connected
Ambient conditions
Temperature
Storage
-40 to 70°C
Fixed installation
-40 to 70°C
Flexible installation
-40 to 70°C
-10 to 50°C
Mechanical properties
Dimensions
Length
3 m
5 m
10 m
15 m
20 m
30 m
50 m
100 m
Diameter
6.7 mm
8.3 mm
Bend radius
Fixed installation
≥5x diameter
≥4x diameter
Flexible installation
≥10x diameter
≥8x diameter
Weight
250 g
500 g
700 g
950 g
2150 g
3500 g
6950 g
Tension
In operation
≤70 N
≤110 N
During installation
≤70 N
≤110 N
Table 20: 5CASD3.0030-00, 5CASD3.0050-00, 5CASD3.0100-00, 5CASD3.0150-00,
5CASD3.0200-00, 5CASD3.0300-00, 5CASD3.0500-00, 5CASD3.1000-00 - Technical data
1)
Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)