Device-specific HART commands:   
Four Electrode Conductivity (EC) 

Command

Description

186

Read PV Sensor Configuration

187

Write Measurement Type

188

Write Sensor Group

189

Read Concentration Configuration

190

Write Concentration Solution

191

Write Concentration Text Display

192

Read Temperature Sensor and Compensation 
Configuration

193

Write Automatic Temperature Compensation Option

194

Write Temperature Compensation Coefficient

195

Read Temperature Compensation Curve Part1

196

Read Temperature Compensation Curve Part 2

197

Read Temperature Compensation Curve Part 3

198

Read Temperature Compensation Curve Part 4

199

Reset PV and Temperature Calibration

204

Read Stable PV for edit during 1 point PV Calibration

205

Read Calibration Mode and Status

206

Write Calibration Mode and Status

207

Write Calibration Value

208

Read Calibration Progress and Error

209

Read Factory Calibration Parameters

211

Write Factory Calibration Parameters

212

Read Factory Calibration Slope and Offset

Table 6  Device-specific HART commands:  
Four Electrode Conductivity (EC) 

Device-specific HART commands:  
pH

Command

Description

213

Read PV Sensor Configuration

214

Write Measurement Type

215

Write pH Sensor Type

216

Write Reference Impedance Limit

217

Write Isopotential pH and Asymmetric Potential

218

Read ION Concentration Configuration

219

Write ION Concentration Configuration

220

Read Temperature Sensor and Compensation 
Configuration

221

Write pH Solution Coefficient Value

222

Write millivolt Solution Coefficient Value

223

Read Primary Variable Transfer Function Curve Part 1

224

Write Primary Variable Transfer Function Curve Part 1

225

Read Two Point Manual Calibration Parameters 

226

Write Two Point Manual Calibration Parameters

227

Reset PV and Temperature Calibration

228

Read the Stable PV for edit during 1 point PV 
Calibration

229

Read PV Calibration Slope and Offset Alarm Limits

230

Write PV Calibration Slope and Offset Alarm Limits

231

Read Auto-Buffer Calibration Parameters

232

Write Standard Buffer Type

233

Write Buffer 1 and Buffer 2 Values

234

Read Calibration Mode and Status

235

Write Calibration Mode and Status

236

Read Temperature Compensated Buffer Value

237

Write Calibration Value

238

Read Calibration Progress and Error

239

Read User Defined Buffer Table 1 Temperature and pH

240

Write User Defined Buffer Table 1 Temperature and pH

241

Read User Defined Buffer Table 2 Temperature and pH

242

Write User Defined Buffer Table 2 Temperature and pH

244

Read Factory Calibration Parameters

245

Write Factory Calibration Parameters

246

Read Factory Calibration Slope and Offset

247

Write Linearity/Function Generator

248

Read Linearity/Function Generator

Table 7  Device-specific HART commands: pH

Acknowledgements

•  Fieldbus is a registered trademark of the Fieldbus Foundation 
•  HART is a registered trademark of the FieldComm Group
•  Modbus is a registered trademark of Schneider Electric USA Inc.
•  PROFIBUS is a registered trademark of PROFIBUS organization.

Summary of Contents for AWT210

Page 1: ...al information on installation operation and maintenance For more information Further publications for the AWT210 transmitter are available for free download from www abb com measurement or by scannin...

Page 2: ...Transmitter functionality and operator interface controls 6 Process interface 6 Sensor Input Channels 6 Host interface 6 Analog output 6 Local interfaces jumpers and switches 6 Local controls and dis...

Page 3: ...RNING BODILY INJURY Installation operation maintenance and servicing must be performed by suitably trained personnel only in accordance with the information provided in this manual in accordance with...

Page 4: ...or disposal at no charge to the user ABB is committed to ensuring that the risk of any environmental damage or pollution caused by any of its products is minimized as far as possible IMPORTANT NOTE Fo...

Page 5: ...re sensor ORP Oxidation reduction potential DDL Device description language HART Highway addressable remote transducer HHT Hand held terminal Reference documents Document ID Title DS AWT210 EN AWT210...

Page 6: ...tory settings If powered up with SW1 in the OFF position the device retains previously saved user settings SW2 Write Protection If SW2 is in the ON position HW write protect shows as enabled and the u...

Page 7: ...022 amps x R ohms Load resistance must include any meters external to the AWT210 transmitter the wiring and the system input IMPORTANT NOTE The equation for minimum supply voltage is based on a maximu...

Page 8: ...tters on the bus Each transmitter on the bus is wired from the primary communication device to the positive and negative POWER SIGNAL terminals of the AWT210 Connect all transmitters on the bus in par...

Page 9: ...by enabling PDM compatibility at the following menu Device Setup PDM Compatibility Enable Device specific HART commands general Command Description 122 Login to Service Level 123 Read Board Object 124...

Page 10: ...Parameters 164 Read Factory Calibration Slope and Offset 252 Read PV Sensor Config Table 4 Device specific HART commands Two Electrode conductivity TE Device specific HART commands Toroidal Conductiv...

Page 11: ...figuration 220 Read Temperature Sensor and Compensation Configuration 221 Write pH Solution Coefficient Value 222 Write millivolt Solution Coefficient Value 223 Read Primary Variable Transfer Function...

Page 12: ...to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB AG does not accept any responsibility wh...

Reviews: