ABB AWT210 Manual Download Page 10

10

AW T 210

  H A R T  2- W I R E  T R A N SM I T T ER  |  CO M/AW T 2 10/H A R T- EN  R E V.  B

… 5  Appendix

…Supported HART commands

Device--specific HART commands:  
Two Electrode conductivity (TE)

Command

Description

144

Write Measurement Type

145

Write Cell Constant

146

Read Concentration Configuration

147

Write Concentration Display Text

148

Read Temperature Sensor and Compensation 
Configuration

149

Write Automatic Temperature Compensation Option

150

Write Temperature Compensation Coefficient

151

Write Temperature Compensation Pure H2O Option

152

Read Temperature Compensation Curve

153

Write Temperature Compensation Curve

154

Read Concentration Curve

155

Write Concentration Curve

156

Reset PV and Temperature Calibration

157

Read Stable Value for edit during 1 point PV 
Calibration

158

Read Calibration Mode and Status

159

Write Calibration Mode and Status

160

Write Calibration Value

161

Read Calibration Progress and Error Status

162

Read Factory Calibration Parameters

163

Write Factory Calibration Parameters

164

Read Factory Calibration Slope and Offset

252

Read PV Sensor Config

Table 4  Device--specific HART commands: 
Two Electrode conductivity (TE)

Device-specific HART commands:  
Toroidal Conductivity (TC) 

Command

Description

165

Read PV Sensor Configuration

166

Write Measurement Type

167

Read Concentration Configuration

169

Write Concentration Display Text

170

Read Temperature Sensor and Compensation 
Configuration

171

Write Automatic Temperature Compensation Option

172

Write Temperature Compensation Coefficient

173

Read Temperature Compensation Curve Part1

174

Read Temperature Compensation Curve Part 2

175

Read Temperature Compensation Curve Part 3

176

Read Temperature Compensation Curve Part 4

177

Reset PV and Temperature Calibration

178

Read Stable PV for edit during 1 point PV Calibration

179

Read Calibration Mode and Status

180

Write Calibration Mode and Status

181

Write Calibration Value

182

Read Calibration Progress and Error

183

Read Factory Calibration Parameters

184

Write Factory Calibration Parameters

185

Read Factory Calibration Slope and Offset

253

Write Concentration Solution 

Table 5  Device-specific HART commands: 
Toroidal Conductivity (TC) 

Summary of Contents for AWT210

Page 1: ...al information on installation operation and maintenance For more information Further publications for the AWT210 transmitter are available for free download from www abb com measurement or by scannin...

Page 2: ...Transmitter functionality and operator interface controls 6 Process interface 6 Sensor Input Channels 6 Host interface 6 Analog output 6 Local interfaces jumpers and switches 6 Local controls and dis...

Page 3: ...RNING BODILY INJURY Installation operation maintenance and servicing must be performed by suitably trained personnel only in accordance with the information provided in this manual in accordance with...

Page 4: ...or disposal at no charge to the user ABB is committed to ensuring that the risk of any environmental damage or pollution caused by any of its products is minimized as far as possible IMPORTANT NOTE Fo...

Page 5: ...re sensor ORP Oxidation reduction potential DDL Device description language HART Highway addressable remote transducer HHT Hand held terminal Reference documents Document ID Title DS AWT210 EN AWT210...

Page 6: ...tory settings If powered up with SW1 in the OFF position the device retains previously saved user settings SW2 Write Protection If SW2 is in the ON position HW write protect shows as enabled and the u...

Page 7: ...022 amps x R ohms Load resistance must include any meters external to the AWT210 transmitter the wiring and the system input IMPORTANT NOTE The equation for minimum supply voltage is based on a maximu...

Page 8: ...tters on the bus Each transmitter on the bus is wired from the primary communication device to the positive and negative POWER SIGNAL terminals of the AWT210 Connect all transmitters on the bus in par...

Page 9: ...by enabling PDM compatibility at the following menu Device Setup PDM Compatibility Enable Device specific HART commands general Command Description 122 Login to Service Level 123 Read Board Object 124...

Page 10: ...Parameters 164 Read Factory Calibration Slope and Offset 252 Read PV Sensor Config Table 4 Device specific HART commands Two Electrode conductivity TE Device specific HART commands Toroidal Conductiv...

Page 11: ...figuration 220 Read Temperature Sensor and Compensation Configuration 221 Write pH Solution Coefficient Value 222 Write millivolt Solution Coefficient Value 223 Read Primary Variable Transfer Function...

Page 12: ...to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB AG does not accept any responsibility wh...

Reviews: