46
AQUA M A STE R4
| EL EC T R O M AG N E T I C FLO W M E T ER T R A N SM I T T ER | O I/FE T4 0 0 - EN R E V. D
…7 Operation
Data transmission via cellular NB (FEX45X)
Additional transmitter configuration is required before normal
operation.
Note
:
Below are the additional configuration to be done for normal
operation along with those as per
1
Enable
Advanced Access Level Enable
in
User Access Right
Settings
and navigate to
Advanced Settings – Cellular NB >
Operation mode
.
2
Click the edit icon and select
Disabled
and tap the phone/
tablet to the device to disable Cellular NB communication.
3
Configure the below parameters through Velox interface app
under
Advance Settings – Cellular NB
and tap the phone/
tablet to the device to update the parameters.
Item
Description
Data report time base
e.g. 0 (to set the base time for
sending report at 00:00 h), the
value should be in seconds.
Data report interval
1 hour / 6 hour / 12 hour / 1 day
Data report mode
Detail report / summary report
Alarm report on raise condition
Off / On
Alarm report on clear condition
Off / On
4
In case of Detail report,
Logging interval & Retrieved record
interval
needs to configure under Process Logger Settings.
5
Transmitter supports optional SIM card configurations in
Advance Settings – Cellular NB
.
• SIM card pin: The transmitter supports to set PIN for un-
authorized access by setting the PIN in
Advance Settings –
Cellular NB > SIM card pin .
• Lock SIM card: Select
On
in
Advance Settings – Cellular NB
> Lock SIM card
to lock the SIM card with the PIN as per
above.
• Unlock SIM Card: Select
On
in
Advance Settings – Cellular
NB > Unlock SIM card
to unlock the SIM card with the PIN as
per above.
• SIM card PUK: If the PIN is lost, the transmitter allow
customer to enter PUK (Personal Unblocking Key) for the
SIM card with the reset PIN code under
Advance Settings –
Cellular NB > SIM card puk
.
6
Navigate to
Advanced Settings – Cellular NB > Operation
mode
.
7
Click the edit icon and select
Enabled
and hover the phone/
tablet to the transmitter to enable Cellular 4G
communication.
8
Reboot the transmitter through Velox by selecting
On
in
Firmware Information > Reboot system
and hover the
phone/tablet to device and the transmitter is now ready for
normal operation.
Data report for FEX45X
The measured data from the device will be transferred by the
transmitter periodically based on the configuration. Below are
examples of different types of data report.
Note
:
In case of NB Transmitter, the file type is JSON only.
Summary report
The summary report contains summary information for
measured data in a period based on configured data report
interval.
Figure 68 Example of summary report in JSON format
Figure 69 Example of summary report in CSV format