![ABB ACSM1 Series Manual Download Page 395](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326395.webp)
Standard function blocks
395
Operation
Reads the internal (non-scaled) value of the source of a pointer parameter. The pointer
parameter is specified using the Group and Index inputs.
The value of the source selected by the pointer parameter is provided by the Output pin.
Error codes are indicated by the error output (Error) as follows:
Inputs
Parameter group (Group): DINT
Parameter index (Index): DINT
Outputs
Output (Output): Boolean, INT, DINT, REAL, REAL24
Error output (Error): DINT
PARWR
(10080)
Illustration
Execution time
14.50 µs
Operation
The input value (IN) is written to the defined parameter (Group and Index).
The new parameter value is stored to the flash memory if the store input (Store) is 1.
Note:
Cyclic parameter value storing can damage the memory unit. Parameter values
should be stored only when necessary.
Error codes are indicated by the error output (Error) as follows:
Inputs
Input (IN): DINT
Parameter group input (Group): DINT
Parameter index input (Index): DINT
Store input (Store): Boolean
Outputs
Error output (Error): DINT
Error code
Description
0
No error or busy
<> 0
Error
PARWR
75
TLA1 1 msec
(1)
IN
Group
Index
Store
Error
Error(75)
Error code
Description
0
No error
<> 0
Error
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...