![ABB ACSM1 Series Manual Download Page 252](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326252.webp)
Parameters and firmware blocks
252
Group
71 POSITION CTRL
Settings for the position controller.
The position controller calculates a speed reference that is used to minimise the
difference between position reference and actual values. The user can set the
controller gain, the feed forward value and a cyclical delay between the reference
and the actual value. The output of the position controller has a gear for transferring
position and speed data from the load side to the motor side.
The position controller also supervises the error between the reference position and
actual position in position and synchron control modes. The drive trips on a
POSITION ERROR fault if the limit (
) is exceeded.
71.05 POS CTRL DELAY
+
71.03 P CTRL FEED GAIN
4.17 POS REF LIMITED
4.01 SPEED REF POS
4.20 SPEED FEED FWD
1.12 POS ACT
71.08 GEAR RATIO DEN
71.07 GEAR RATIO NUM
z
-x
x
y
x
y
4.02 SPEED ACT LOAD
1.01 SPEED ACT
x
y
x
4.19 POS ERROR
71.02 POS CTRL GAIN
+
-
d
dt
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...