![ABB ACSM1 Series Hardware Manual Download Page 74](http://html1.mh-extra.com/html/abb/acsm1-series/acsm1-series_hardware-manual_3346607074.webp)
Technical data
74
Dimensions and weights
See also the chapter
.
Note:
The wiring to the I/O options requires some 50 mm (2”) of additional depth.
Cooling characteristics, noise levels
Cold plate cooling characteristics (ACSM1-04Cx-xxxx-x only)
The ratings stated at the beginning of this chapter are achieved provided that the
hot-spot temperature of the cold plate is kept below 65 °C (140 °F) and that the drive
is installed according to the instructions in this manual.
A suitable cold plate is, for example, the Rittal DCP 8616.xxx (Direct Cooling
Package) intended for Rittal TS8 enclosures. If the incoming coolant temperature is
below 50 °C (122 °F), and the flow is at least 5 dm
3
/min, the cooling is adequate.
The temperature rise of the coolant due to the drive is approximately 1…2 K
maximum.
The ACSM1-04Cx-xxxx-x has an internal fan to cool the circuit boards. The heat
dissipation into air is approximately 200 W.
Frame
size
Height
(without
cable clamp
plates)
Height
(with
cable clamp
plates)
Width
Depth
(without options
installed on
JCU)
Depth
(with options
installed on
JCU)
Weight
mm (in.)
mm (in.)
mm (in.)
mm (in.)
mm (in.)
kg (lbs)
A
364 (14.33)
474 (18.66)
90 (3.54)
146 (5.75)
169 (6.65)
2.8 (6.2)
B
380 (14.96)
476 (18.74)
100 (3.94)
223 (8.78)
246 (9.69)
4.8 (10.6)
C
467 (18.39)
558 (21.97)
165 (6.50)
235 (9.25)
248 (9.76)
10 (22)
D
467 (18.39)
558 (21.97)
220 (8.66)
235 (9.25)
248 (9.76)
17 (37.5)
Drive type
ACSM1-04xx…
Power loss
W
Air flow
(ACSM1-04A…)
m
3
/h
Air flow
(ACSM1-04C…)
m
3
/h
Noise level
dBA
-02A5-4
100
24
N/A
47
-03A0-4
106
24
N/A
47
-04A0-4
126
24
N/A
47
-05A0-4
148
24
N/A
47
-07A0-4
172
24
N/A
47
-09A5-4
212
48
N/A
39
-012A-4
250
48
N/A
39
-016A-4
318
48
N/A
39
-024A-4
375
142
24
63
-031A-4
485
142
24
63
-040A-4
541
200
24
71
-046A-4
646
200
24
71
-060A-4
840
290
24
70
-073A-4
1020
290
24
70
-090A-4
1200
290
24
70
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Hardware Manual ACSM1 04 Drive Modules 0 75 to 45 kW...
Page 2: ......
Page 4: ......
Page 14: ...Table of contents 14...
Page 20: ...About this manual 20...
Page 24: ...The ACSM1 04 24...
Page 30: ...Planning the cabinet assembly 30...
Page 46: ...Planning the electrical installation 46...
Page 70: ...Maintenance 70...
Page 84: ...Technical data 84...
Page 90: ...Mains filters 90...
Page 96: ...Dimension drawings 96 Frame size A...
Page 97: ...Dimension drawings 97...
Page 98: ...Dimension drawings 98 Frame size B...
Page 99: ...Dimension drawings 99...
Page 100: ...Dimension drawings 100 Frame size C air cooled module...
Page 101: ...Dimension drawings 101...
Page 102: ...Dimension drawings 102 Frame size C for cold plate mounting...
Page 103: ...Dimension drawings 103 Frame size D air cooled module...
Page 104: ...Dimension drawings 104 Frame size D for cold plate mounting...
Page 106: ...Dimension drawings 106 Mains filters type JFI xx...
Page 108: ...Dimension drawings 108 Braking resistors type JBR xx...
Page 110: ...Dimension drawings 110...
Page 111: ......