Parameters and firmware blocks
154
Group
These parameters select the data to be sent by the drive to the fieldbus controller,
and need to be set only if a fieldbus adapter module is installed. See also
on page
Notes:
• This parameter group is presented in the
User’s Manual
of the fieldbus adapter as
parameter group 3 or C.
• The new settings will take effect when the drive is powered up the next time
(before powering off the drive, wait at least 1 minute), or when parameter
is activated.
• The maximum number of data words is protocol-dependent.
52
52 FBA DATA IN
52.01
FBA DATA IN1
FW block: None
Selects data to be transferred from the drive to the fieldbus controller.
0
Not in use.
4
Status Word (16 bits).
5
Actual value 1 (16 bits).
6
Actual value 2 (16 bits).
14
Status Word (32 bits).
15
Actual value 1 (32 bits).
16
Actual value 2 (32 bits).
101…9999
Parameter index.
52.02
FBA DATA IN2
FW block: None
…
…
52.12
FBA DATA IN12
FW block: None
See
.