310 Parameters
Defines the 2nd frequency point on the X-axis of the user load
curve.
25.0 Hz
0.0 … 500.0 Hz
Frequency.
1 = 1 Hz
Defines the 3rd frequency point on the X-axis of the user load
curve.
43.0 Hz
0.0 … 500.0 Hz
Frequency.
1 = 1 Hz
Defines the 4th frequency point on the X-axis of the user load
curve.
50.0 Hz
0.0 … 500.0 Hz
Frequency.
1 = 1 Hz
Defines the 5th frequency point on the X-axis of the user load
curve.
60.0 Hz
0.0 … 500.0 Hz
Frequency.
1 = 1 Hz
Defines the 1st point of the underload curve.
Each point of the underload curve must have a lower value
than the corresponding overload point.
10.0%
0.0 … 1600.0%
Underload point.
1 = 1%
Defines the 2nd point of the underload curve.
15.0%
0.0 … 1600.0%
Underload point.
1 = 1%
Defines the 3rd point of the underload curve.
25.0%
0.0 … 1600.0%
Underload point.
1 = 1%
Defines the 4th point of the underload curve.
30.0%
0.0 … 1600.0%
Underload point.
1 = 1%
Defines the 5th point of the underload curve.
30.0%
0.0 … 1600.0%
Underload point.
1 = 1%
Defines the 1st point of the overload curve.
Each point of the overload curve must have a higher value
than the corresponding underload point.
300.0%
0.0 … 1600.0%
Overload point.
1 = 1%
Defines the 2nd point of the overload curve.
300.0%
0.0 … 1600.0%
Overload point.
1 = 1%
Defines the 3rd point of the overload curve.
300.0%
0.0 … 1600.0%
Overload point.
1 = 1%
Defines the 4th point of the overload curve.
300.0%
0.0 … 1600.0%
Overload point.
1 = 1%
Defines the 5th point of the overload curve.
300.0%
0.0 … 1600.0%
Overload point.
1 = 1%
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...