The Drive Composer PC tool has an Adaptive programming feature with a graphical
user interface for building the custom program. The function blocks include the
usual arithmetic and logical functions, as well as eg. selection, comparison and
timer blocks. The program can contain a maximum of 50 blocks. The adaptive
program is executed on a 10 ms time level.
For selecting input to the program, the user interface has pre-selections for the
physical inputs, common actual values, and other status information of the drive.
Parameter values as well as constants can also be defined as inputs. The output
of the program can be used eg. as a start signal, external event or reference, or
connected to the drive outputs. Note that connecting the output of the adaptive
program to a selection parameter will write-protect the parameter.
The status of the adaptive program is shown by parameter
. The adaptive
program can be disabled by
.
Please note that sequential programming is not supported.
For more information, see the
Adaptive programming application guide
(3AXD50000028574 [English]).
Settings and diagnostics
Parameters:
7.30 Adaptive program status (page 171)
and
Events:
64A6 Adaptive program (page 561)
■
Application programming
The Position control program includes a ready-made application program for
position control applications. The application program project file and motion
library, both needed to modify the program, are not yet available for ABB customers.
If modification is needed, contact your local ABB representative for support.
Note: Application programmability (lN8010) is standard with the position
control program. It is possible to download a new IEC application program to the
memory unit, but this will replace the orN5700 application program, and
is not recommended because operation with the APCFx firmware requires expert
programming knowledge. If the application program is inadvertently downloaded,
it is recommended to download the original loading package (APCLx) again.
For more information, see
Programming manual: Drive application programming
(IEC 61131-3) (3AUA0000127808 [English]).
Control interfaces
■
Programmable analog inputs
The control unit has two programmable analog inputs. Each of the inputs can be
independently set as a voltage (0/2…10 V or -10…10 V) or current (0/4…20 mA)
Program features 63
Summary of Contents for ACS880 N5700 Series