112 Technical data
Nominal ratings with 500 V AC supply
Definitions
Drive type
ACS880-M04
Frame
size
Input
ratings
Output ratings
Nominal
No-overload
use
Light-
overload use
Heavy-
duty use
I
1N
*I
1N
I
2N
I
Max
P
N
I
Ld
P
Ld
I
Hd
P
Hd
A
A
A
A
kW
A
kW
A
kW
-03A0-5
R1
2.3
3.8
3.0
4.4
1.5
2.8
1.1
2.5
1.1
-03A6-5
R1
3.1
5.6
3.6
5.3
1.5
3.4
1.5
3.0
1.5
-04A8-5
R1
4.0
6.8
4.8
7.0
2.2
4.5
2.2
4.0
2.2
-06A0-5
R1
5.5
9.4
6.0
8.8
3.0
5.5
3.0
5.0
2.2
-08A0-5
R1
6.6
11.2
8.0
10.5
4.0
7.6
4.0
6.0
3.0
-010A-5
R2
8.7
13
10.5 13.5
5.5
9.7
5.5
9.0
4.0
-014A-5
R2
12
18
14
16.5
7.5
13.0
7.5
11.0 5.5
-018A-5
R2
16
23
18
21
11.0
16.8
7.5
14.0 7.5
-025A-5
R3
20
–
25
33
15.0
23
11.0
19.0 11.0
-030A-5
R3
26
–
30
36
18.5
28
15.0
24
15.0
-035A-5
R3
30
–
35
44
22
32
18.5
29
18.5
-044A-5
R3
36
–
44
53
30
41
22
35
22
-050A-5
R3
42
–
50
66
30
46
30
44
30
-061A-5
R4
55
–
61
78
37
57
37
52
30
-078A-5
R4
65
–
78
104
45
74
45
66
45
-094A-5
R4
82
–
94
124
55
90
55
75
45
3AXD10000434191
See symbol definitions below.
I
1N
Nominal input current (rms) at 40 °C (104 °F).
*Without mains choke.
I
2N
Nominal output current.
I
Max
Maximum output current. Available for at least 10 seconds at start, otherwise as long
as allowed by drive temperature.
P
N
Typical motor power for no-overload use.
I
Ld
Continuous rms output current. 10% overload is allowed for 1 minute every 5 minutes.
P
Ld
Typical motor power for light-overload use.
I
Hd
Continuous rms output current. 50% overload is allowed for 1 minute every 5 minutes.
P
Hd
Typical motor power for heavy-duty use.
Note:
To achieve the rated motor power given in the table, the rated current of the drive must
be higher than or equal to the rated motor current.
The DriveSize dimensioning tool available from ABB is recommended for selecting the drive,
motor and gear combination.
The maximum allowed motor shaft power is limited to 1.5 ·
P
Hd
, 1.1 ·
P
N
or
P
cont.max
(whichever value is the greatest). If the limit is exceeded, motor torque and current are
automatically restricted. The function protects the input bridge of the drive against overload.
Summary of Contents for ACS880-M04
Page 1: ...ABB machinery drives Hardware manual ACS880 M04 drive ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Safety instructions ...
Page 28: ...28 About the manual ...
Page 38: ...38 Operation principle and hardware description ...
Page 48: ...48 Planning the cabinet installation ...
Page 54: ...54 Mechanical installation ...
Page 72: ...72 Planning the electrical installation ...
Page 98: ...98 Electrical installation ...
Page 102: ...102 Start up ...
Page 108: ...108 Maintenance ...
Page 140: ...140 Technical data ...
Page 158: ...158 Mains chokes ...
Page 164: ...164 EMC filters 7 Attach the terminal blocks to the filter 1 6 5 4 3 ...
Page 166: ...166 EMC filters 6 Attach the terminal blocks to the filter 1 2 3 4 ...
Page 168: ...168 EMC filters ...
Page 182: ...Dimension drawings 182 Frame size R1 H1 H2 W D ...
Page 183: ...Dimension drawings 183 Frame size R2 H2 H1 W D ...
Page 184: ...Dimension drawings 184 Frame size R3 D W H1 H2 ...
Page 185: ...Dimension drawings 185 Frame size R4 W H1 H2 D ...
Page 187: ...187 Dimension drawings EMC filters type JFI x1 JFI A1 ...
Page 188: ...Dimension drawings 188 JFI B1 ...
Page 189: ...189 Dimension drawings EMC filters type JFI 0x ...
Page 191: ...191 Dimension drawings Brake resistors type JBR xx ...
Page 193: ...193 Dimension drawings ...
Page 195: ...www abb com drives www abb com drivespartners 3AXD50000028613 Rev A EN 2016 04 11 Contact us ...