Work on the liquid cooling system
These instructions are intended for all personnel that do installation, commissioning and
maintenance work on the liquid cooling system.
WARNING!
Obey these instructions. If you ignore them, injury or death, or damage to the
equipment can occur.
•
Use the required personal protective equipment. See the Safety data sheet for
Antifrogen
®
L coolant by Clariant (www.clariant.com) for the instructions on the
respiratory, hand and eye protection when handling the coolant.
•
Beware of hot, high-pressure coolant (6 bar, max. 50 °C) that is present in the internal
cooling circuit when it is in operation. Before you disconnect a pipe, release the pressure.
Close the appropriate stop valve(s). If necessary, stop the cooling circuit pumps.
•
Avoid skin contact with coolant. If coolant splashes onto the skin or in the eyes, rinse
immediately with plenty of water. Do not syphon it by mouth. If you swallow or get it
into the eyes, seek medical advice.
•
Before the drive power up, make sure that the internal cooling circuit is filled up with
coolant, and the cooling is in operation (coolant is circulating).
•
Make sure that coolant meets the ABB specification. See the appropriate hardware
manual of the drive/unit.
•
To avoid breaking the coolant pipes, do not overtighten the nuts of the unions. Leave
2 to 3 millimeters (0.08 to 0.12 inches) of thread visible.
2…3 mm (0.08 … 0.12″)
•
Do not drain coolant into the sewer system.
•
If you need to store the drive in temperature below -15 °C (5 °F), drain the cooling
circuit, or make sure that it is filled with the coolant specified by ABB.
•
Drives with the cooling unit: Do not open the cooling unit pump inlet or outlet valves
before filling up the coolant circuit. The pumps are filled with a mixture at the factory to
prevent corrosion and the valves are closed at the factory.
•
Drives with the cooling unit: Do not run the cooling unit pump dry.
18 Safety instructions
3
Summary of Contents for ACS880-37LC-0390A-7
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 37LC drives Hardware manual ...
Page 2: ......
Page 4: ......
Page 13: ...16 Resistor braking Further information Table of contents 13 ...
Page 14: ...14 ...
Page 24: ...24 ...
Page 28: ...28 ...
Page 50: ...50 ...
Page 70: ...70 Mechanical installation ...
Page 110: ...10 110 Electrical installation ...
Page 113: ...With FDPI 02 modules OPEN TERMINATED 1 1 2 2 OPEN TERMINATED 3 Electrical installation 113 11 ...
Page 134: ...134 ...
Page 140: ...140 ...
Page 148: ...a b c 148 Maintenance ...
Page 151: ...4 5 6 Maintenance 151 ...
Page 164: ...164 ...
Page 174: ...174 ...
Page 196: ...196 ...
Page 199: ... Dimension drawing examples ACS880 37LC 0390A 7 with main contactor Dimensions 199 ...
Page 201: ...ACS880 37LC 1270A 7 with common motor terminal cubicle Dimensions 201 ...
Page 202: ...ACS880 37LC 1940A 7 with common motor terminal cubicle 202 Dimensions ...
Page 205: ...Location and size of input terminals Contact ABB for details Dimensions 205 ...
Page 206: ... 100 kA input cubicle option F274 206 Dimensions ...
Page 208: ...Inverter module cubicle with two R8i modules bottom cable exit 208 Dimensions ...
Page 209: ...Inverter module cubicle with three R8i modules bottom cable exit Dimensions 209 ...
Page 210: ...Brake chopper cubicle 210 Dimensions ...
Page 212: ...Cubicle width 300 mm top cable exit 212 Dimensions ...
Page 213: ...Cubicle width 400 mm bottom cable exit Dimensions 213 ...
Page 214: ...Cubicle width 400 mm top cable exit 214 Dimensions ...
Page 215: ...Cubicle width 600 mm bottom cable exit Dimensions 215 ...
Page 216: ...Cubicle width 600 mm top cable exit 216 Dimensions ...
Page 238: ...238 ...
Page 240: ...240 ...