![ABB ACS880-34 Hardware Manual Download Page 121](http://html.mh-extra.com/html/abb/acs880-34/acs880-34_hardware-manual_2653121.webp)
Internal control unit (P905) 121
Connecting the control cables to the internal control unit (option
+P905)
1. Ground the outer control cable shields 360 degrees at the cabinet entry plate
(recommendation).
2. Remove the middle front cover of the drive module (view of standard drive module
configuration below).
3. Fasten the clamp plate to the bottom of the control unit with two screws from front, see
Attaching the control cable clamp plate
4. Fasten the optional modules if not fastened already.
5. Remove the cover plate from the control cable entry and put the rubber grommet in its
place. Put the control cables through the grommet.
Note
: If you route the control cables from top or bottom instead of front or side, you
need tho make holes for the entries to the clear plastic shrouds.
6. Ground the control cables at the clamp plate as described in Step 2 in section
Connecting the control cables to the terminals of the control unit
7. Connect the conductors to the appropriate detachable terminals of the control unit
(see page
). Use shrink tubing or insulating tape to contain any stray strands.
Tighten the screws to secure the connection.
Note:
Keep any signal wire pairs twisted as close to the terminals as possible.
Twisting the wire with its return wire reduces disturbances caused by inductive
coupling.
8. Install the middle front cover back.
Combi screw
M4×8 Torx T20
2 N·m
2
5
5
3
Summary of Contents for ACS880-34
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 34 drive modules 132 to 400 kW 200 to 450 hp Hardware manual ...
Page 4: ......
Page 14: ...14 ...
Page 22: ...22 Safety instructions ...
Page 28: ...28 Introduction to the manual ...
Page 42: ...42 Operation principle and hardware description ...
Page 118: ...118 External control unit ...
Page 140: ...140 Installation example with full cabling panels option H381 M8 16 Hex 2 5 4 3 1 1 1 1 2 6 7 ...
Page 152: ...152 Installation checklist ...
Page 156: ...156 Start up ...
Page 158: ...158 Fault tracing ...
Page 174: ...174 Maintenance ...
Page 202: ...202 Technical data EU Declaration of Conformity Machinery Directive ...
Page 204: ...204 Technical data ...
Page 206: ...206 Dimension drawings Standard configuration 3AXD50000038012 ...
Page 208: ...208 Dimension drawings Drive module with options 0B051 H356 0H371 3AXD50000038012 ...
Page 209: ...Dimension drawings 209 Configuration with option H381 3AXD50000323210 ...
Page 210: ...210 Dimension drawings LCL filter module 3AXD50000206162 ...
Page 214: ...214 Dimension drawings External control unit 3axd50000011687 ...
Page 238: ...238 Resistor braking ...
Page 242: ...242 du dt and sine filters ...
Page 256: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035191 Rev B EN 2018 09 28 ...