Introduction to the manual 9
1
Introduction to the manual
Contents of this chapter
This chapter describes the manual in short and gives some general information for the
reader. The chapter also contains a quick reference for implementing a safety system.
Applicability
This manual applies to ACS880-07/17/37 drives which have the Q979:
Emergency stop, configurable stop category 0 or 1 with STO, with FSO. In this emergency
stop option, the Safe torque off (STO) circuit of the drive is opened. The main contactor/
breaker of the drive is not opened.
For the Q979, ABB installs the FSO-12 safety functions module (Q973) or
the FSO-21 safety functions module (Q972) to the drive. When a safety pulse
encoder is used, ABB installs the FSE-31 pulse encoder interface module (L521)
and the FSO-21 module to the drive. Only the FSO-21 module supports the FSE-31
module and the use of safety pulse encoders.
Required versions with the FSO-12 module:
•
ACS880 primary control program: 1.80 or later
•
FSO-12 safety functions module: revision C or later
•
Drive composer pro: 1.6
or later.
Required versions with the FSO-21 module:
•
ACS880 primary control program: 2.2 or later
•
FSO-21 safety functions module: revision D or later
•
FSE-31 pulse encoder interface module: revision D or later (if used)
•
Drive composer pro: 1.8 or later.
Summary of Contents for ACS880-17
Page 4: ......
Page 7: ...7 Document library on the Internet 57...
Page 8: ...8...
Page 34: ...34 Option description and instructions...
Page 48: ...48 Start up and acceptance test...
Page 56: ...56 Technical data...
Page 58: ...3AUA0000145921 Rev E EN 2018 02 02 Contact us www abb com drives www abb com drivespartners...