BDCL filter module
A
B
6
6
3
4
5
1
2
2
1
7
Filter module, front
A
Filter module, back
B
Energy storage connection
1
Terminal block [X30], temperature control
2
The unpainted grounding point
3
Handle
4
Type designation label of the module
5
Quick connector
6
Converter module connection
7
■
Overheating protection of the filter
By default, the BDCL filter is protected against overheating (caused by a faulty fan, for
example) with a thermistor and the temperature monitoring function of the control program.
If the filter temperature becomes too high, the temperature monitoring function stops the
DC/DC converter module automatically.