Installing the charging circuit
The cabinet builder must install and connect the charging circuit. For connections, see the
example circuit diagrams. Consult ABB for more information on the components and wirings
needed.
Activate and tune the charging function in the control program. For information on tuning
the parameters, see
ACS880 DC/DC converter control program firmware manual
(3AXD50000024671 [English]).
Connecting the external power supply cable for the auxiliary
circuit
■
R8i DC/DC converter module
The cabinet builder must arrange an auxiliary voltage of 230 V AC (or 115 V AC with option
+G304) to connector X50 to power the electronics of the DC/DC converter module. R8i
modules contain a power supply (BDPS) that produces 24 V DC from the auxiliary voltage
for the internal circuit boards. The 24 V DC voltage provided by the BDPS is available on
X53, and can used to power up one BCU control unit. It is not allowed to use the 24 V DC
output on terminal X53 for any other purpose than for powering up the BCU control unit.
■
BDCL filter module
For the filter connectors, see the hardware description. For the details about supply voltage
levels and auxiliary circuit current consumption, see the technical data.
68 Electrical installation
Summary of Contents for ACS880-1604LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 1604LC DC DC converter modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 16: ...16 ...
Page 34: ...34 ...
Page 42: ...Kits for ACS880 1604LC R8i unit in Rittal VX25 cabinets 42 Cabinet construction ...
Page 43: ...Stage 1 Installation of common parts Cabinet construction 43 10 ...
Page 45: ...Stage 3 Module installation parts Cabinet construction 45 10 ...
Page 46: ...Stage 4 DDC and energy storage connection 46 Cabinet construction ...
Page 47: ...Stage 5A DC connection with charging Cabinet construction 47 10 ...
Page 48: ...Stage 5B DC connection without charging 48 Cabinet construction ...
Page 49: ...Stage 6 Cooling components Cabinet construction 49 10 ...
Page 50: ...Stage 7 DDC module and filter installation 50 Cabinet construction ...
Page 51: ...Stage 8 Swing frame and shroud installation Cabinet construction 51 10 ...
Page 58: ...58 ...
Page 72: ...72 ...
Page 124: ...124 ...
Page 138: ...138 ...
Page 148: ...148 ...
Page 150: ...R8i DC DC converter module 150 Dimension drawings ...
Page 151: ...BDCL filter module Dimension drawings 151 ...
Page 152: ...Quick connector 152 Dimension drawings ...
Page 153: ...BCU control unit Dimension drawings 153 ...
Page 154: ...BAMU voltage current measurement unit Dimensions in mm 1 mm 0 0394 in 154 Dimension drawings ...