![ABB ACS880-1604 Hardware Manual Download Page 166](http://html.mh-extra.com/html/abb/acs880-1604/acs880-1604_hardware-manual_2645166.webp)
166 Control unit
Control unit connector data
Power supply
(XPOW)
Connector pitch 5 mm, wire size 2.5 mm
2
24 V (±10%) DC, 2 A
External power supply in. Two supplies can be connected to BCU
for redundancy.
Relay outputs RO1…RO3
(XRO1…XRO3)
Connector pitch 5 mm, wire size 2.5 mm
2
250 V AC / 30 V DC, 2 A
Protected by varistors
+24 V output
(XD24:2 and XD24:4)
Connector pitch 5 mm, wire size 2.5 mm
2
Total load capacity of these outputs is 4.8 W (200 mA / 24 V) minus
the power taken by DIO1 and DIO2.
Digital inputs DI1…DI6 (XDI:1…XDI:6)
Connector pitch 5 mm, wire size 2.5 mm
2
24 V logic levels: “0” < 5 V, “1” > 15 V
R
in
: 2.0 kohm
Input type: NPN/PNP (DI1…DI5), NPN (DI6)
Hardware filtering: 0.04 ms, digital filtering up to 8 ms
DI6 (XDI:6) can alternatively be used as an input for a PTC
thermistor.
“0” > 4 kohm, “1” < 1.5 kohm
I
max
: 15 mA (DI1…DI5), 5 mA (DI6)
Start interlock input DIIL
(XDI:7)
Connector pitch 5 mm, wire size 2.5 mm
2
24 V logic levels: “0” < 5 V, “1” > 15 V
R
in
: 2.0 kohm
Input type: NPN/PNP
Hardware filtering: 0.04 ms, digital filtering up to 8 ms
Digital inputs/outputs DIO1 and DIO2
(XDIO:1 and XDIO:2)
Input/output mode selection by
parameters.
DIO1 can be configured as a frequency
input (0…16 kHz with hardware filtering
of 4 microseconds) for 24 V level square
wave signal (sinusoidal or other wave
form cannot be used). DIO2 can be
configured as a 24 V level square wave
frequency output. See the firmware
manual of the supply unit
,
parameter
group 111.
Connector pitch 5 mm, wire size 2.5 mm
2
As inputs:
24 V logic levels: “0” < 5 V, “1” > 15 V
R
in
: 2.0 kohm
Filtering: 1 ms
As outputs:
Total output current from +24VD is limited to 200 mA
Reference voltage for analog inputs
+VREF and -VREF
(XAI:1 and XAI:2)
Connector pitch 5 mm, wire size 2.5 mm
2
10 V ±1% and –10 V ±1%,
R
load
1…10 kohm
Maximum output current: 10 mA
Analog inputs AI1 and AI2
(XAI:4 … XAI:7).
Current/voltage input mode selection by
switches.
Connector pitch 5 mm, wire size 2.5 mm
2
Current input: –20…20 mA,
R
in:
100 ohm
Voltage input: –10…10 V,
R
in
: 200 kohm
Differential inputs, common mode range ±30 V
Sampling interval per channel: 0.25 ms
Hardware filtering: 0.25 ms, adjustable digital filtering up to 8 ms
Resolution: 11 bit + sign bit
Inaccuracy: 1% of full scale range
R
L
DIOx
DIOGND
+24VD
Summary of Contents for ACS880-1604
Page 1: ...ABB industrial drives Hardware manual ACS880 1604 DC DC converter modules ...
Page 4: ......
Page 12: ...12 ...
Page 36: ...36 Operation principle and hardware description ...
Page 45: ...Cabinet construction 45 Kits for DDC R8i unit in 800 mm Rittal TS 8 enclosure ...
Page 46: ...46 Cabinet construction Stage 1 Installation of common parts ...
Page 47: ...Cabinet construction 47 Stage 2 Module and bottom cable entry installation parts ...
Page 49: ...Cabinet construction 49 Stage 4A DC connection with charging ...
Page 50: ...50 Cabinet construction Stage 4B DC connection without charging ...
Page 51: ...Cabinet construction 51 Stage 5A DC connection with charging ...
Page 52: ...52 Cabinet construction Stage 5B DC connection without charging ...
Page 53: ...Cabinet construction 53 Stage 6 DDC and energy storage connection ...
Page 54: ...54 Cabinet construction Stage 7 Control unit mounting plate ...
Page 55: ...Cabinet construction 55 Stage 8 DDC shroud installation ...
Page 56: ...56 Cabinet construction Stage 9 DDC module and filter installation ...
Page 58: ...58 Cabinet construction Kits for DDC R8i unit in 800 mm wide generic enclosure ...
Page 64: ...64 Guidelines for planning electrical installation ...
Page 80: ...80 Electrical installation ...
Page 97: ...Maintenance 97 7 3 4 5 6 ...
Page 99: ...Maintenance 99 3 4 5 6 7 8 9 9 ...
Page 102: ...102 Maintenance 12 Install and tighten the two screws 10 11 12 ...
Page 108: ...108 Maintenance 6 6 6 7 5 4 ...
Page 109: ...Maintenance 109 8 9 8 ...
Page 112: ...112 Maintenance 4 4 ...
Page 113: ...Maintenance 113 6 6 5 7 7 8 ...
Page 170: ...170 Dimension drawings R8i DC DC converter module ...
Page 171: ...Dimension drawings 171 ...
Page 172: ...172 Dimension drawings Quick connectors of the DC DC converter module ...
Page 173: ...Dimension drawings 173 Quick connectors Dimensions in mm 1 mm 0 0394 in ...
Page 174: ...174 Dimension drawings BDCL filter module ...
Page 176: ...176 Dimension drawings BCU control unit ...
Page 177: ...Dimension drawings 177 BAMU voltage current measurement unit ...
Page 179: ...Dimension drawings 179 Ramp Dimensions in mm 1 mm 0 0394 in ...
Page 180: ...180 Dimension drawings Dimensions in mm 1 mm 0 0394 in ...
Page 181: ...Dimension drawings 181 Internal cabinet fan W2E 143 AA09 01 W2E 143 AA15 01 Air flow ...
Page 190: ...190 Dimension drawings ...
Page 194: ...194 Example circuit diagrams ...
Page 222: ...www abb com drives www abb com drivespartners 3AXD50000023642 Rev B EN 2017 02 08 Contact us ...