The main cooling fan is located at the top of the module. The replacement of the main
cooling fan requires that the module is pulled outwards far enough to create room above
the module.
1.
Stop the drive and do the steps in section
Electrical safety precautions (page 57)
before
you start the work.
2.
Remove the air baffles shown:
•
Upper-row module: (2a) above the module
•
Lower-row module: (2b) above the module.
2b
2b
2b
2a
3.
Disconnect all cabling from the module. Move the cables aside.
4.
Remove the four mounting nuts and screws of the module (two at the top edge, two at
the bottom edge).
5.
Pull the module carefully outwards along its rails until the fan at the top is accessible.
WARNING!
Do not pull the module out any further than what is required to change the fan
(unless you intend to remove the module completely). The rails have no stops
to prevent the module from sliding all the way out.
6.
Lift the fan mounting plate by the front edge.
7.
Unplug the power supply wires.
8.
Lift out the fan assembly.
Install the new fan assembly and insert the module in reverse order to the above. Make
sure that the fan blows upwards.
Replacing the R5i module main cooling fan (with C204)
WARNING!
Obey the instructions in chapter Safety instructions. If you ignore them,
injury or death, or damage to the equipment can occur.
WARNING!
Read the safety instructions given in
Safety instructions for ACS880
multidrive cabinets and modules
(3AUA0000102301 [English]). If you
ignore them, injury or death, or damage to the equipment can occur.
The main cooling fan is located at the top of the module.
104 Maintenance
Summary of Contents for ACS880-107
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 107 inverter units Hardware manual ...
Page 2: ......
Page 4: ......
Page 10: ...10 ...
Page 64: ...2 4 5 6 7 8 11 10 3 a b a b b 1 5 a 64 Electrical installation ...
Page 69: ...Electrical installation 109 5 6 4 3 Electrical installation 69 11 ...
Page 70: ...7 a b d c 110 Electrical installation 7 8 8 8 9 9 70 Electrical installation ...
Page 75: ...2 11 b PE 10 7 5 6 8 a 360 grounding detail Electrical installation 75 11 ...
Page 89: ...With FDPI 02 modules OPEN TERMIN ATED 1 1 2 2 OPEN TERMINATED 3 Electrical installation 89 11 ...
Page 90: ...90 ...
Page 96: ...96 ...
Page 110: ...4 5 6 7 8 6 10 10 110 Maintenance ...
Page 118: ...2 3 7 9 a a c c c 6 8 b b d d 11 e e 118 Maintenance ...
Page 121: ...7 a b d c 110 Electrical installation 7 8 8 8 9 9 Maintenance 121 ...
Page 130: ...130 ...
Page 154: ...154 ...
Page 155: ...Circuit diagrams Refer to the circuit diagrams delivered with the unit 9 Circuit diagrams 155 ...
Page 156: ...156 ...
Page 159: ... Dimension drawing 400 mm wide cubicle R1i R4i 400 mm R6i R7i Dimensions and weights 159 ...
Page 161: ... Dimension drawing R8i without C128 or H353 bottom cable exit Dimensions and weights 161 ...
Page 162: ... Dimension drawing R8i without C128 or H353 top cable exit 162 Dimensions and weights ...
Page 163: ... Dimension drawing 2 R8i without C128 or H353 bottom cable exit Dimensions and weights 163 ...
Page 164: ... Dimension drawing 2 R8i without C128 or H353 top cable exit 164 Dimensions and weights ...
Page 165: ... Dimension drawing 3 R8i without C128 or H353 bottom cable exit Dimensions and weights 165 ...
Page 166: ... Dimension drawing 3 R8i without C128 or H353 top cable exit 166 Dimensions and weights ...
Page 167: ... Dimension drawing drive control unit DCU 300 mm Dimensions and weights 167 ...
Page 169: ...Inverter module cubicle with one R8i module top cable exit Dimensions and weights 169 ...
Page 182: ...182 ...
Page 200: ...200 ...