Fuses
■
AC fuses
Notes:
•
Fuses with higher current rating than the recommended ones must not be used.
•
Fuses from other manufacturers can be used if they meet the ratings and the melting
curve of the fuse does not exceed the melting curve of the fuse mentioned in the table.
Ultrarapid (aR) fuses at supply module input
ACS880-07CLC-…
Type
Manufacturer
V
A
2
s at
660 V
A
Qty
U
N
= 690 V, 6-pulse connection
170M6467
Bussmann
690
2450000
1400
3
0390A…0850A-7
6
1030A…1660A-7
9
1940A…2470A-7
12
2880A…3260A-7
U
N
= 690 V, 12-pulse connection
170M6467
Bussmann
690
2450000
1400
6
0530A…1660A-
7+A004
12
1940A…3260A-
7+A004
18
3580A…4840A-
7+A004
24
5650A…6460A-
7+A004
U
N
= 690 V, 24-pulse connection
170M6467
Bussmann
690
2450000
1400
12
2470A…3260A-
7+A006
24
4840A…6460A-
7+A006
■
DC fuses
The drive has DC fuses at the input of each inverter module.
Notes:
•
Fuses with higher current rating than the recommended ones must not be used.
•
Fuses from other manufacturers can be used if they meet the ratings and the melting
curve of the fuse does not exceed the melting curve of the fuse mentioned in the table.
DC fuses at inverter module input
ACS880-07CLC-…
Type
Manufacturer
V
A
Qty
U
N
= 690 V, 6-pulse connection
PC73UD13C800TF
Ferraz Shawmut
1250
800
2
0390A-7
0430A-7
170M6547
Bussmann
1100
900
2
0480A-7
170M6548
Bussmann
1100
1000
2
0530A-7
170M6549
Bussmann
1000
1100
2
0600A-7
170M6500
Bussmann
1100
1250
2
0670A-7
Technical data 157
Summary of Contents for ACS880-07CLC
Page 1: ...ABB industrial drives Hardware manual ACS880 07CLC drives ...
Page 2: ......
Page 4: ......
Page 64: ...64 ...
Page 82: ...82 ...
Page 91: ...PE PE 10 13 12 22 Electrical installation 91 ...
Page 122: ...122 ...
Page 124: ...124 ...
Page 132: ...5 4 11 7 6 8 132 Maintenance ...
Page 133: ...14 15 16 12 13 17 Maintenance 133 ...
Page 141: ...5 Set the real time clock Maintenance 141 ...
Page 142: ...142 ...
Page 150: ...150 ...
Page 176: ...ACS880 07CLC 0390A 7 C121 marine construction 176 Dimensions ...
Page 177: ...ACS880 07CLC 1310A 7 Dimensions 177 ...
Page 178: ...ACS880 07CLC 2180A 7 C121 marine construction 178 Dimensions ...
Page 179: ...ACS880 07CLC 3260A 7 C121 marine construction Dimensions 179 ...
Page 181: ... 2 D8D Dimensions 181 ...
Page 182: ... 3 D8D 182 Dimensions ...
Page 183: ... 4 D8D Dimensions 183 ...
Page 185: ...Inverter module cubicle with two R8i modules bottom cable exit Dimensions 185 ...
Page 186: ...Inverter module cubicle with three R8i modules bottom cable exit 186 Dimensions ...
Page 187: ...Brake chopper cubicle D150 Dimensions 187 ...
Page 188: ...188 ...
Page 202: ...202 ...
Page 211: ......
Page 212: ......
Page 214: ...Contact us www abb com drives 3AXD50000131457 Rev A EN EFFECTIVE 2018 03 09 3AXD50000131457A ...