132 Technical data
Efficiency
Approximately 98% at nominal power level
Protection classes
Degree of protection
(IEC/EN 60529)
Front: IP20
Front with 0B051: IP00
Heatsink: IP55
Enclosure type (UL 508C)
Front: UL Open Type
Front with 0B051: UL Open Type
Heatsink: NEMA Type 12
Overvoltage category
(IEC 60664-1)
III
Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a
heated, indoor, controlled environment.
Operation
installed for stationary
use
Storage
in the protective
package
Transportation
in the protective
package
Installation site altitude
For TN and TT neutral-
grounded network
systems and IT non-
corner grounded
network systems:
0 to 4000 m (13123 ft)
above sea level
For TN, TT and IT
corner-grounded
network systems:
0 to 2000 m (6561 ft)
above sea level
Above 1000 m [3281 ft]),
see page
.
-
-
Air temperature
-15 to +55 °C
(5 to 131 °F).
No frost
-40 to +70 °C
(-40 to +158 °F)
-40 to +70 °C
(-40 to +158 °F)
Relative humidity
5 to 95%
Max. 95%
Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the
presence of corrosive gases.
Contamination levels
IEC/EN 60721-3-3:2002:
Classification of
environmental
conditions- Part 3-3:
Classification of groups
of environmental
parameters and their
severities - Stationary
use of weather protected
locations
IEC 60721-3-1:1997
IEC 60721-3-2:1997
Chemical gases
Class 3C2
Class 1C2
Class 2C2
Solid particles
Class 3S2. No
conductive dust allowed.
Class 1S3. (packing
must support this,
otherwise 1S2)
Class 2S2
Pollution degree
2
Atmospheric pressure
70 to 106 kPa
0.7 to 1.05 atmospheres
70 to 106 kPa
0.7 to 1.05 atmospheres
60 to 106 kPa
0.6 to 1.05 atmospheres
Summary of Contents for ACS880-04F
Page 1: ...ABB industrial drives Hardware manual ACS880 04F drive modules ...
Page 4: ......
Page 24: ...24 Introduction to the manual ...
Page 46: ...46 Guidelines for planning the mechanical installation ...
Page 102: ...102 Installation checklist ...
Page 106: ...106 Fault tracing ...
Page 135: ...Technical data 135 Declaration of Conformity ...
Page 136: ...136 Technical data ...
Page 140: ...140 Technical data ...
Page 142: ...142 Dimension drawings Standard configuration IP20 UL Open Type ...
Page 143: ...Dimension drawings 143 Drive module with options E208 and H370 IP20 UL Open Type ...
Page 144: ...144 Dimension drawings Drive module with options 0B051 E208 0H371 IP00 UL Open Type ...
Page 145: ...Dimension drawings 145 Drive module with options 0B051 E208 0H371 C217 IP00 UL Open Type ...
Page 146: ...146 Dimension drawings Drive module with options 0B051 0H371 IP00 UL Open Type ...
Page 147: ...Dimension drawings 147 Mounting plate 3AXD50000038119 ...
Page 148: ...148 Dimension drawings 3AXD50000038119 ...
Page 149: ...Dimension drawings 149 External control unit 3axd50000011687 ...
Page 150: ...150 Dimension drawings ...
Page 164: ...164 Safe torque off function ...