ZCU-1x ground isolation diagram
XPOW
+24VI
1
GND
2
XAI
+VREF
1
-VREF
2
AGND
3
AI1+
4
AI1-
5
AI2+
6
AI2-
7
XAO
AO1
1
AGND
2
AO2
3
AGND
4
XD2D
B
1
A
2
BGND
3
XRO1, XRO2, XRO3
NC
11
COM
12
NO
13
NC
21
COM
22
NO
23
NC
31
COM
32
NO
33
XD24
DIIL
1
+24VD
2
DICOM
3
+24VD
4
DIOGND
5
XDIO
DIO1
1
DIO2
2
XDI
DI1
1
DI2
2
DI3
3
DI4
4
DI5
5
DI6
6
XSTO
OUT1
1
GND
2
IN1
3
IN2
4
*
Common mode voltage between
channels ±30 V
* Ground selector (J6) settings
All digital inputs share a common ground (DICOM connected to DIOGND). This is the default setting.
Ground of digital inputs DI1…DI5 and DIIL (DICOM) is isolated from DIO signal ground (DIOGND).
Isolation voltage 50 V.
110 Control unit of the drive
Summary of Contents for ACS880-04F-504A-3
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 04F drive modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 50: ...50 Mechanical installation ...
Page 56: ...56 ...
Page 116: ...116 ...
Page 122: ...4 3 2 122 Maintenance ...
Page 128: ...128 ...
Page 143: ... Package dimensions Package dimensions without IP shroud kit Technical data 143 ...
Page 158: ...158 ...
Page 160: ...Standard configuration IP20 UL Type Open 160 Dimension drawings ...
Page 161: ...Drive module with options E208 and H370 IP20 UL Type Open Dimension drawings 161 ...
Page 162: ...Drive module with options 0B051 E208 0H371 IP00 UL Type Open 162 Dimension drawings ...
Page 163: ...Drive module with options 0B051 E208 0H371 C217 IP00 UL Type Open Dimension drawings 163 ...
Page 164: ...Drive module with options 0B051 0H371 IP00 UL Type Open 164 Dimension drawings ...
Page 165: ...Mounting plate opening 3AXD50000038119 Dimension drawings 165 ...
Page 166: ...3AXD50000038119 166 Dimension drawings ...
Page 167: ...External control unit 3AXD50000011687 Dimension drawings 167 ...
Page 168: ...168 ...