Fault tracing 375
0002 Feed constant definition invalid
or outside limits.
Check feed constant settings (
and
0003 Motor/load gear definition
invalid or outside limits.
Check motor/load gear settings (
0004 Encoder not configured.
Check encoder settings (
).
) to validate any changes in the
settings.
0005 Encoder stopped working.
Check encoder status.
73B0
Emergency ramp
failed
Emergency stop did not finish
within expected time.
Check the settings of parameters
Emergency ramp supervision delay
.
Check the predefined ramp times
(
for mode Off1,
for
mode Off3).
73B1
Stop failed
Ramp stop did not finish within
expected time.
Check the settings of parameters
Check the predefined ramp times in
parameter group
.
73F0
Overfrequency
Maximum allowed output
frequency exceeded.
Without a dual-use license, the fault limit
is 598 Hz. Contact your local ABB
representative for dual-use licensing
information.
7510
FBA A communication
Cyclical communication
between drive and fieldbus
adapter module A or between
PLC and fieldbus adapter
module A is lost.
Check status of fieldbus communication.
See user documentation of fieldbus
interface.
Check settings of parameter groups
Check cable connections.
Check if communication master is able to
communicate.
7581
DDCS controller
comm loss
DDCS controller comm
loss function
DDCS (fiber optic)
communication between drive
and external controller is lost.
Check status of controller. See user
documentation of controller.
Check settings of parameter group
.
Check cable connections. If necessary,
replace cables.
7582
MF comm loss
Master/follower
communication is lost.
(page
).
7583
Line side unit faulted
The supply unit (or other
converter) connected to the
inverter unit has generated a
fault.
The auxiliary code specifies the original
fault code in the supply unit control
program. See section
Auxiliary codes for
line-side converter faults
(page
539
).
Code
(hex)
Fault
Cause
What to do
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...