124 Parameters
Const
). -
Pointer
21.05
Speed share
Defines the scaling factor for speed reference 1/2 (speed
reference 1 or 2 is multiplied by the defined value). Speed
reference 1 or 2 is selected by parameter
-8.000 …8.000
Speed reference scaling factor.
1000 = 1
21.07
Speed ref jog1
Defines the speed reference for jogging function 1. For more
information on jogging, see page
-30000 … 30000
rpm
Speed reference for jogging function 1.
1 = 1 rpm
21.08
Speed ref jog2
Defines the speed reference for jogging function 2. For more
information on jogging, see page
-30000 … 30000
rpm
Speed reference for jogging function 2.
1 = 1 rpm
21.09
SpeedRef min abs
Defines the absolute minimum limit for the speed reference.
0 … 30000 rpm
Absolute minimum limit for speed reference.
1 = 1 rpm
21.10
Mot pot func
Selects whether the value of the motor potentiometer is
retained upon drive power-off.
Reset
Drive power-off resets the value of the motor potentiometer.
0
Store
The value of the motor potentiometer is retained over drive
power-off.
1
21.11
Mot pot up
Selects the source of motor potentiometer up signal.
DI4
Digital input DI4 (as indicated by
, bit 3).
1073938945
DI5
Digital input DI5 (as indicated by
, bit 4).
1074004481
DI6
Digital input DI6 (as indicated by
, bit 5).
1074070017
Const
). -
Pointer
No.
Name/Value
Description
FbEq
-(
)
Speed reference
Limited speed reference