Parameters 223
64.21
AL1 70 to 80%
Percentage of samples recorded by amplitude logger 1 that
fall between 70 and 80%.
0.00 … 100.00%
Amplitude logger 1 samples between 70 and 80%.
100 = 1%
64.22
AL1 80 to 90%
Percentage of samples recorded by amplitude logger 1 that
fall between 80 and 90%.
0.00 … 100.00%
Amplitude logger 1 samples between 80 and 90%.
100 = 1%
64.23
AL1 over 90%
Percentage of samples recorded by amplitude logger 1 that
exceed 90%.
0.00 … 100.00%
Amplitude logger 1 samples over 90%.
100 = 1%
64.24
AL2 0 to 10%
Percentage of samples recorded by amplitude logger 2 that
fall between 0 and 10%.
0.00 … 100.00%
Amplitude logger 2 samples between 0 and 10%.
100 = 1%
64.25
AL2 10 to 20%
Percentage of samples recorded by amplitude logger 2 that
fall between 10 and 20%.
0.00 … 100.00%
Amplitude logger 2 samples between 10 and 20%.
100 = 1%
64.26
AL2 20 to 30%
Percentage of samples recorded by amplitude logger 2 that
fall between 20 and 30%.
0.00 … 100.00%
Amplitude logger 2 samples between 20 and 30%.
100 = 1%
64.27
AL2 30 to 40%
Percentage of samples recorded by amplitude logger 2 that
fall between 30 and 40%.
0.00 … 100.00%
Amplitude logger 2 samples between 30 and 40%.
100 = 1%
64.28
AL2 40 to 50%
Percentage of samples recorded by amplitude logger 2 that
fall between 40 and 50%.
0.00 … 100.00%
Amplitude logger 2 samples between 40 and 50%.
100 = 1%
64.29
AL2 50 to 60%
Percentage of samples recorded by amplitude logger 2 that
fall between 50 and 60%.
0.00 … 100.00%
Amplitude logger 2 samples between 50 and 60%.
100 = 1%
64.30
AL2 60 to 70%
Percentage of samples recorded by amplitude logger 2 that
fall between 60 and 70%.
0.00 … 100.00%
Amplitude logger 2 samples between 60 and 70%.
100 = 1%
64.31
AL2 70 to 80%
Percentage of samples recorded by amplitude logger 2 that
fall between 70 and 80%.
0.00 … 100.00%
Amplitude logger 2 samples between 70 and 80%.
100 = 1%
64.32
AL2 80 to 90%
Percentage of samples recorded by amplitude logger 2 that
fall between 80 and 90%.
0.00 … 100.00%
Amplitude logger 2 samples between 80 and 90%.
100 = 1%
64.33
AL2 over 90%
Percentage of samples recorded by amplitude logger 2 that
exceed 90%.
0.00 … 100.00%
Amplitude logger 2 samples over 90%.
100 = 1%
No.
Name/Value
Description
FbEq
Summary of Contents for ACS850-04 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Page 4: ......
Page 10: ...10 Table of contents...
Page 52: ...52 The ACS850 control panel...
Page 56: ...56 Control locations and operating modes...
Page 80: ...80 Program features...
Page 236: ...236 Parameters...
Page 286: ...286 Fieldbus control...
Page 294: ...294 Control block diagrams...