Technical data
83
Technical data
What this chapter contains
This chapter contains the technical specifications of the drive, e.g. the ratings, sizes
and technical requirements, provisions for fulfilling the requirements for CE and
other markings, and warranty policy.
IEC data
Ratings
The IEC ratings for the ACS800-04 with 50 Hz and 60 Hz supplies are given below.
The symbols are described below the table.
ACS800-04
size
Nominal ratings
No-
overload
use
Light-overload use Heavy-duty use
Frame
size
Air flow
Heat
dissipation
I
cont.max
A
I
max
A
P
cont.max
kW
I
2N
A
P
N
kW
I
2hd
A
P
hd
kW
m
3
/h
W
Three-phase supply voltage 208 V, 220 V,
230 V
or 240 V
-0080-2
214
326
55
211
55
170
45
R7
540
2900
-0100-2
253
404
75
248
75
202
55
R7
540
3450
-0120-2
295
432
90
290
90
240
4)
55
R7
540
4050
-0140-2
405
588
110
396
110
316
90
R8
1220
5300
-0170-2
447
588
132
440
132
340
90
R8
1220
6100
-0210-2
528
588
160
516
160
370
110
R8
1220
6700
-0230-2
613
840
160
598
160
480
132
R8
1220
7600
-0260-2
693
1017
200
679
200
590
2)
160
R8
1220
7850
-0300-2
720
1017
200
704
200
635
3)
200
R8
1220
8300
Three-phase supply voltage 380 V,
400 V
or 415 V
-0140-3
206
326
110
202
110
163
90
R7
540
3000
-0170-3
248
404
132
243
132
202
110
R7
540
3650
-0210-3
289
432
160
284
160
240
1)
132
R7
540
4300
-0260-3
445
588
200
440
200
340
160
R8
1220
6600
-0320-3
521
588
250
516
250
370
200
R8
1220
7150
-0400-3
602
840
315
590
315
477
250
R8
1220
8100
-0440-3
693
1017
355
679
355
590
2)
315
R8
1220
8650
-0490-3
720
1017
400
704
400
635
3)
355
R8
1220
9100
Summary of Contents for ACS800-04
Page 4: ......
Page 12: ...Safety instructions 12 ...
Page 54: ...Planning the electrical installation 54 ...
Page 72: ...Motor control and I O board RMIO 72 ...
Page 116: ...Resistor braking 116 ...
Page 117: ......