![ABB ACS580-04 Hardware Manual Download Page 189](http://html.mh-extra.com/html/abb/acs580-04/acs580-04_hardware-manual_2579189.webp)
UL (NEC)
1)
ACS580-04-…
Cu cable
AWG/kcmil per phase
U
n
= 400 V
2 × 500 MCM or 3 × 250 MCM
505A-4
2 × 600 MCM or 3 × 300 MCM
585A-4
2 × 700 MCM or 3 × 350 MCM
650A-4
3 × 500 MCM or 4 × 300 MCM
725A-4
3 × 600 MCM or 4 × 400 MCM
820A-4
3 × 600 MCM or 4 × 400 MCM
880A-4
U
n
= 480 V
2 × 400 MCM or 3 × 4/0
505A-4
2 × 500 MCM or 3 × 250 MCM
585A-4
2 × 600 MCM or 3 × 300 MCM
650A-4
2 × 700 MCM or 3 × 350 MCM
725A-4
3 × 500 MCM or 4 × 300 MCM
820A-4
3 × 600 MCM or 4 × 400 MCM
880A-4
1) The cable sizing is based on NEC Table 310-16 for copper wires, 75 °C wire insulation at 40 °C ambient temperature.
Not more than three current-carrying conductors in raceway or cable or earth (directly buried). For other conditions,
size the cables according to local safety regulations, appropriate input voltage and the load current of the drive.
Terminal data for the control cables
See chapter
.
Electrical power network specification
ACS580-04-xxxx-4 drive modules: 380…480 V AC 3-phase ±10%. This is indic-
ated in the type designation label as typical input voltage levels
3~400/480 V AC.
Voltage (
U
1
)
TN (grounded) and IT (ungrounded) systems
Network type
Maximum permitted prospective short-circuit current is 65 kA when protected
by the fuses given in the fuse table.
Rated conditional short-
circuit current I
cc
(IEC 61439-1)
Maximum permitted prospective short-circuit current is 65 kA when protected
by the fuses given in the fuse table.
Prospective short-cir-
cuit current rating Pscc
(IEC 61800-5-1)
The drive is suitable for use on a circuit capable of delivering not more than
100000 rms symmetrical amperes at 480 V maximum when protected by the
fuses given in the fuse table.
Prospective short-cir-
cuit current rating SCCR
(UL 61800-5-1)
48…63 Hz, maximum rate of change 17%/s
Frequency
Max. ± 3% of nominal phase to phase input voltage
Imbalance
0.98 (at nominal load)
Fundamental power
factor (cos phi
1
)
Technical data 189
Summary of Contents for ACS580-04
Page 1: ... ABB GENERAL PURPOSE DRIVES ACS580 04 drive modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 60: ...60 ...
Page 69: ...2 1 Tapping screw M6 12 Torx T30 Hex 9 N m 6 6 lbf ft Mechanical installation 69 10 ...
Page 72: ...72 ...
Page 100: ...100 ...
Page 120: ...120 ...
Page 128: ...2 7a 7b 5 3 3 7a 7b 8a 8b 8b 4 128 Installation example with full cabling panels option H381 ...
Page 133: ...Installation example with full cabling panels option H381 133 ...
Page 134: ...134 ...
Page 146: ...146 ...
Page 157: ...External control unit option P906 157 ...
Page 162: ...162 ...
Page 164: ...164 ...
Page 200: ...R10 standard configuration 200 Dimension drawings ...
Page 201: ...R10 with options E208 0H354 H356 H370 0H371 Dimension drawings 201 ...
Page 202: ...R10 with option B051 202 Dimension drawings ...
Page 203: ...R10 with options E208 H356 P906 Dimension drawings 203 ...
Page 204: ...R10 with options E208 0H371 H356 0H354 H370 P906 204 Dimension drawings ...
Page 205: ...R10 with options B051 P906 Dimension drawings 205 ...
Page 208: ...R11 standard configuration 208 Dimension drawings ...
Page 209: ...R11 with options E208 0H371 H356 0H354 H370 Dimension drawings 209 ...
Page 210: ...R11 with option B051 210 Dimension drawings ...
Page 211: ...R11 with options E208 H356 P906 Dimension drawings 211 ...
Page 212: ...R11 with options E208 0H371 H356 0H354 H370 P906 212 Dimension drawings ...
Page 213: ...R11 with options B051 P906 Dimension drawings 213 ...
Page 248: ...248 ...
Page 260: ...260 ...
Page 265: ...CHDI 01 115 230 V digital input extension module 265 ...
Page 266: ...266 ...
Page 272: ...272 CMOD 01 multifunction extension module external 24 V AC DC and digital I O ...
Page 278: ...278 ...
Page 280: ...280 ...