![ABB ACS580-04 Hardware Manual Download Page 187](http://html.mh-extra.com/html/abb/acs580-04/acs580-04_hardware-manual_2579187.webp)
Losses, cooling data and noise
Noise
Typical power
loss
1)
Air flow
Frame
size
ACS580-04…
W
cfm
m
3
/h
dB(A)
72
6492
707
1200
R10
505A-4
72
6840
707
1200
R10
585A-4
72
8046
707
1200
R10
650A-4
72
8108
707
1200
R11
725A-4
72
9652
707
1200
R11
820A-4
71
10887
848
1420
R11
880A-4
1) Typical drive losses when it operates at 90% of the motor nominal frequency and 100% of the motor nominal
current.
Terminal and entry data for the power cables
The maximum accepted cable size is 4 × (3 × 240) mm
2
or 4 × (3 × 500 MCM). Screw
size for connecting busbars to the drive module input and output busbars: M12,
tightening torque 50…75 N·m (37…55 lbf·ft).
■
Drive modules without output cable connection terminals (+0H371)
and with a common mode filter (+E208)
It is possible to use the maximum cable size 4 × (3 × 240) mm
2
or 4 × (3 × 500 MCM)
only with special cable lugs and additional insulation. For more information, contact
your local ABB representative.
■
Drive modules with optional cabling panels (+H381)
The maximum accepted cable size is 4 × (3 × 240) mm
2
or 4 × (3 × 500 MCM). The
cabling panels are connected to the drive module busbars with M12 serpress nuts,
tightening torque 30 N·m (20 lbf·ft).
Technical data 187
Summary of Contents for ACS580-04
Page 1: ... ABB GENERAL PURPOSE DRIVES ACS580 04 drive modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 60: ...60 ...
Page 69: ...2 1 Tapping screw M6 12 Torx T30 Hex 9 N m 6 6 lbf ft Mechanical installation 69 10 ...
Page 72: ...72 ...
Page 100: ...100 ...
Page 120: ...120 ...
Page 128: ...2 7a 7b 5 3 3 7a 7b 8a 8b 8b 4 128 Installation example with full cabling panels option H381 ...
Page 133: ...Installation example with full cabling panels option H381 133 ...
Page 134: ...134 ...
Page 146: ...146 ...
Page 157: ...External control unit option P906 157 ...
Page 162: ...162 ...
Page 164: ...164 ...
Page 200: ...R10 standard configuration 200 Dimension drawings ...
Page 201: ...R10 with options E208 0H354 H356 H370 0H371 Dimension drawings 201 ...
Page 202: ...R10 with option B051 202 Dimension drawings ...
Page 203: ...R10 with options E208 H356 P906 Dimension drawings 203 ...
Page 204: ...R10 with options E208 0H371 H356 0H354 H370 P906 204 Dimension drawings ...
Page 205: ...R10 with options B051 P906 Dimension drawings 205 ...
Page 208: ...R11 standard configuration 208 Dimension drawings ...
Page 209: ...R11 with options E208 0H371 H356 0H354 H370 Dimension drawings 209 ...
Page 210: ...R11 with option B051 210 Dimension drawings ...
Page 211: ...R11 with options E208 H356 P906 Dimension drawings 211 ...
Page 212: ...R11 with options E208 0H371 H356 0H354 H370 P906 212 Dimension drawings ...
Page 213: ...R11 with options B051 P906 Dimension drawings 213 ...
Page 248: ...248 ...
Page 260: ...260 ...
Page 265: ...CHDI 01 115 230 V digital input extension module 265 ...
Page 266: ...266 ...
Page 272: ...272 CMOD 01 multifunction extension module external 24 V AC DC and digital I O ...
Page 278: ...278 ...
Page 280: ...280 ...