70
ACS510 User’s Manual
Start-Up
0305
FAULT WORD 1
Read-only copy of the Fault Word 1.
• When a fault is active, the
corresponding bit for the active fault
is set in the Fault Words.
• Each fault has a dedicated bit
allocated within Fault Words.
• See "Fault Listing" on page 197 for a
description of the faults.
• The control panel displays the word
in hex. For example, all zeros and a 1
in Bit 0 displays as 0001. All zeros
and a 1 in Bit 15 displays as 8000.
0306
FAULT WORD 2
Read-only copy of the Fault Word 2.
See parameter 0305.
0307
FAULT WORD 3
Read-only copy of the Fault Word 3.
See parameter 0305.
0308
ALARM WORD 1
• When an alarm is active, the
corresponding bit for the active alarm
is set in the Alarm Words.
• Each alarm has a dedicated bit
allocated within Alarm Words.
• Bits remain set until the whole alarm
word is reset. (Reset by writing zero
to the word.)
• The control panel displays the word
in hex. For example, all zeros and a 1
in Bit 0 displays as 0001. All zeros
and a 1 in Bit 15 displays as 8000.
0309
ALARM WORD 2
See parameter 0308.
Bit # 0305,
FAULT
WORD
1 0306,
FAULT
WORD
2 0307,
FAULT
WORD
3
0
OVERCURRENT
Obsolete EFB
1
1
DC OVERVOLT
THERM FAIL
EFB 2
2
DEV OVERTEMP
OPEX LINK
EFB 3
3
SHORT CIRC
OPEX PWR
INCOMPATIBLE SW
4
Reserved
CURR MEAS
USER LOAD CURVE
5
DC UNDERVOLT
SUPPLY PHASE
Reserved
6
AI1 LOSS
Reserved
Reserved
7
AI2 LOSS
Reserved
Reserved
8 MOT
OVERTEMP Reserved
Reserved
9
PANEL LOSS
DRIVE ID
Reserved
10 Reserved
CONFIG FILE
System error
11 MOTOR STALL
SERIAL 1 ERR
System error
12 CB OVERTEMP
EFB CON FILE System
error
13 EXT FAULT 1
FORCE TRIP
System error
14 EXT FAULT 2
MOTOR PHASE
System error
15
EARTH FAULT
OUTP WIRING
Param. setting fault
Bit #
0308,
ALARM
WORD
1
0309,
ALARM
WORD
2
0
OVERCURRENT
OFF BUTTON
1
OVERVOLTAGE
PID SLEEP
2
UNDERVOLTAGE
Reserved
3
DIRLOCK Reserved
4
COMM LOSS
START ENABLE 1
5
AI1 LOSS
START ENABLE 2
6
AI2 LOSS
EMERGENCY STOP
7
PANEL LOSS
Reserved
8
DEVICE OVERTEMP
Reserved
9
MOTOR TEMP
Reserved
10 Reserved
USER LOAD CURVE
11
MOTOR STALL
START DELAY
12 AUTORESET Reserved
13 PFC AUTOCHANGE
Reserved
14 PFC ILOCK
Reserved
15 Reserved
Reserved
Supplied from China by: Guangzhou Tofee Electro Mechanical Equipment Co., Ltd