Parameters 95
Current day energy consumption. This is the energy
of the last 24 hours (not necessarily continuous) the
drive has been running, not the energy of a calendar
day. The value is set to the value before the power
cycle when the drive is again up and running.
-
0.00…1000000.00 kWh Energy.
1 = 1 kWh
Previous day energy consumption. The value is set to
the value before the power cycle when the drive is
again up and running.
-
0.00 … 1000000.00
kWh
Energy.
1 = 1 kWh
Amount of energy that has passed through the drive
(in either direction) in full kilowatt-hours. The
minimum value is zero.
-
-200000000.0…
200000000.0 kWh
Energy in kWh.
10 = 1 kWh
Amount of energy that has passed through the drive
(in either direction) in full gigawatt-hours. The
minimum value is zero.
You can reset the value by setting it to zero. Resetting
any of parameters
…
resets all of them.
-
0…65535 GWh
Energy in GWh.
1 = 1 GWh
Amount of energy that has passed through the drive
(in either direction) in full megawatt-hours. Whenever
is incremented. The minimum value is
zero.
You can reset the value by setting it to zero. Resetting
any of parameters
…
resets all of them.
-
0…1000 MWh
Energy in MWh.
1 = 1 MWh
Amount of energy that has passed through the drive
(in either direction) in full kilowatt-hours. Whenever
is incremented. The minimum value is
zero.
You can reset the value by setting it to zero. Resetting
any of parameters
…
resets all of them.
-
0…1000 kWh
Energy in kWh.
10 = 1 kWh
Amount of energy that has passed through the drive
(in either direction) in full kilowatt-hours. The
minimum value is zero.
You can reset the value by setting it to zero. Resetting
any of parameters
…
resets all of them.
-
-200000000.0…
200000000.0 kWh
Energy in kWh.
10 = 1 kWh
Absolute value of the motor speed used
.
-
0.00… 30000.00 rpm
1 = 1 rpm
Absolute value of the motor speed %
-
0.00… 1000.00%
10 = 1%
No.
Name/Value
Description
Default
FbEq 16
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...