66 Parameters
Terminal Configuration Options
Terminal Mode: (
1103 = 0
)
9902 Digital input 1
Digital input 2
Digital input 3 (An in 2) Analog input 1
Comments
0
Open: Stop
(disable)
Closed: Run
(enable)
Open: Forward
run
Closed: reverse
run
Open: Analog input 1
Closed: Preset speed 1
Analog input 1
1
Open: Stop
(disable)
Closed: Run
(enable)
Open: Analog
input 1
Closed: Preset
speed 1 / 2
Open: Preset speed 1
Closed: Preset speed 2
Analog input 1
2
Open: Stop
(disable)
Closed: Run
(enable)
Preset Speed
select 0
Preset Speed select 1
Open: Preset
Speed 1...4
Closed: Max
Speed (
2008
)
3
1)
Open: Stop
(disable)
Closed: Run
(enable)
Open: Analog
input 1
Closed: Preset
speed 1
External trip/thermistor
input:
Open: Trip, Closed: Run
Analog input 1
Connect external
thermistor type
PT100 or similar to
digital input 3
4
Open: Stop
(disable)
Closed: Run
(enable)
Open: Analog
input 1
Closed: Analog
input 2
Analog input 2
Analog input 1
Switches between
selected speed ref
and Analog input 2
5
Open: Fwd. Stop
Closed: Fwd. Run
Open: reverse
Stop
Closed: reverse
Run
Open: Analog input 1
Closed: Preset speed 1
Analog input 1
Closing digital
inputs 1 and 2
together carries out
a fast stop
6
1)
Open: Stop
(disable)
Closed: Run
(enable)
Open: Forward
run
Closed: reverse
run
External trip/thermistor
input:
Open: Trip, Closed: Run
Analog input 1
Connect ext.
thermistor type
PT100 or similar to
Digi input 3
7
1)
Open: Fwd. Stop
Closed: Fwd. Run
Open: reverse
Stop
Closed: reverse
Run
External trip/thermistor
input:
Open: Trip, Closed: Run
Analog input 1
Closing digital
inputs 1 and 2
together carries out
a fast stop
8
Open: Stop
(disable)
Closed: Run
(enable)
Open: Forward
run
Closed: reverse
run
Preset Speed select 0
Preset Speed
select 1
9
Open: Fwd. Stop
Closed: Fwd. Run
Open: reverse
Stop
Closed: reverse
Run
Preset Speed select 0
Preset Speed
select 1
Closing digital
inputs 1 and 2
together carries out
a fast stop
10
Normally Open
(NO)
Momentary close
to run
Normally Closed
(NC)
Momentary open
to stop
Open: Analog input 1
Closed: Preset speed 1
Analog input 1
11
Normally Open
(NO)
Momentary close
to run
Normally Closed
(NC)
Momentary open
to stop
Normally Open (NO)
Momentary close to rev
Analog input 1
Closing digital
inputs 1 and 3
together carries out
a fast stop
ACS260-04.book Page 66 Thursday, December 24, 2020 4:33 PM
Summary of Contents for ACS260-04 Series
Page 2: ...ACS260 04 book Page 2 Thursday December 24 2020 4 33 PM ...
Page 4: ...ACS260 04 book Page 4 Thursday December 24 2020 4 33 PM ...
Page 8: ...8 Table of contents ACS260 04 book Page 8 Thursday December 24 2020 4 33 PM ...
Page 14: ...14 Safety ACS260 04 book Page 14 Thursday December 24 2020 4 33 PM ...
Page 22: ...22 Mechanical installation ACS260 04 book Page 22 Thursday December 24 2020 4 33 PM ...
Page 32: ...32 Electrical installation ACS260 04 book Page 32 Thursday December 24 2020 4 33 PM ...
Page 92: ...92 Technical Data ACS260 04 book Page 92 Thursday December 24 2020 4 33 PM ...
Page 96: ...96 Options and Kits ACS260 04 book Page 96 Thursday December 24 2020 4 33 PM ...