Fault tracing 345
5098
I/O communication
loss
Communication failure to
standard I/O.
Try resetting the fault or cycle the power
to the drive.
50A0
Fan
Cooling fan stuck or
disconnected.
Check fan operation and connection.
Replace fan if faulty.
5681
PU communication
Communication errors
detected between the drive
control unit and the power unit.
Check the connection between the drive
control unit and the power unit.
5682
Power unit lost
Connection between the drive
control unit and the power unit
is lost.
Check the connection between the
control unit and the power unit.
5690
PU communication
internal
Internal communication error.
Contact your local ABB representative.
5691
Measurement circuit
ADC
Measurement circuit fault.
Contact your local ABB representative.
5692
PU board powerfail
Power unit power supply
failure.
Contact your local ABB representative.
5693
Measurement circuit
DFF
Measurement circuit fault.
Contact your local ABB representative.
5696
PU state feedback
State feedback from output
phases does not match control
signals.
Contact your local ABB representative.
5697
Charging feedback
Charging feedback signal
missing.
Check the feedback signal coming from
the charging system.
6181
FPGA version
incompatible
Firmware and FPGA versions
are incompatible.
Reboot the control unit (using parameter
) or by cycling
power. If the problem persists, contact
your local ABB representative
6200
Checksum mismatch
Programmable event:
The calculated parameter
checksum does not match any
enabled reference checksum.
See
(page
).
6481
Task overload
Internal fault.
Reboot the control unit (using parameter
) or by cycling
power. If the problem persists, contact
your local ABB representative
6487
Stack overflow
Internal fault.
Reboot the control unit (using parameter
) or by cycling
power. If the problem persists, contact
your local ABB representative
64A1
Internal file load
File read error.
Reboot the control unit (using parameter
) or by cycling
power. If the problem persists, contact
your local ABB representative
64A6
Adaptive program file
incompatible or
corrupted
Adaptive program has faulted.
Check the auxiliary code. See actions for
each code below.
000A
Program corrupted or block
non-existent.
Restore the template program or
download the program to the drive.
000C
Required block input missing.
Check the inputs of the block.
000E
Program corrupted or block
non-existent.
Restore the template program or
download the program to the drive.
Code
(hex)
Fault / Aux. code
Cause
What to do
ACS180 FW.book Page 345 Tuesday, March 9, 2021 2:25 PM