Parameters 111
Absolute value of the output frequency
-
0.00…500.00 Hz
1 = 1 Hz
Absolute value of the motor torque
-
0.0…1600.0%
1 = 1%
Absolute value of the output power
-
0.00…32767.00 kW
1 = 1 kW
Absolute value of the output power % of motor nominal
.
-
0.00… 300.00%
1 = 1%
Absolute value of the motor shaft power
-
0.00…332767.00 kW
1 = 1 kW
03
Values of references received from various sources.
All parameters in this group are read-only unless
otherwise noted.
Local mode reference is given from the control panel.
0
-100000.00…
100000.00 rpm, Hz or
%
Control panel or PC tool reference.
1 = 10 unit
Remote mode reference given from the control panel.
-
-100000.00…
100000.00 rpm, Hz or
%
Control panel or PC tool reference.
1 = 10 unit
Scaled reference 1 received through the embedded
fieldbus interface. The scaling is defined by
-
-30000.00 …
30000.00
Scaled reference 1 received through the embedded
fieldbus interface.
1 = 10
Scaled embedded fieldbus reference 2.
-
-30000.00 …
30000.00
Scaled reference 2 received through the embedded
fieldbus interface. The scaling is defined by
1 = 10
Local mode reference given from the integrated control
panel. The unit (rpm, Hz or %) is set from parameter.
0
-100000.00 …
100000.00 rpm, Hz or
%
Integrated control panel reference.
1 = 10
Remote mode reference given from the integrated control
panel.
0
-100000.00 …
100000.00 rpm, Hz or
%
Integrated control panel reference.
1 = 10
No.
Name/Value
Description
Default
FbEq 16