PREVENTIVE AND CORRECTIVE MAINTENANCE
PRODUCT
ACS1000W
DOCUMENT KIND
User manual
DOCUMENT ID.
3BHS213400 E01
REV.
J
LANG.
en
PAGE
160/166
11.6.10.2. Replacing a battery
1.
When the drive is in operation, disable the battery monitoring function first.
To do this, set parameter
31.05 DISABLE BATTERY TEST
to
ON
.
Parameter
31.05
is automatically set to
OFF
after 1 hour.
2.
Disconnect the wires (1).
3.
Unscrew the battery at the front (2) and at the back (not shown).
Figure 11
-
7 Control compartment - replacing the batteries
4.
Install the new battery in reverse order of removal.
5.
Record the date of battery replacement in the logbook.
CAUTION
Heavy object.
Each battery weighs approximately
10 kg
.
1
1
2
2
2
2