![ABB ACS 6000 User Manual Download Page 202](http://html.mh-extra.com/html/abb/acs-6000/acs-6000_user-manual_2952202.webp)
09 CDP CONTROL PANEL
3BHS212794 E01 REV M
ACS6000
USER MANUAL
202/278
9.2.2
Actual signals mode
Figure 9-2 Control panel functions for Actual signals mode
9.2.2.1
Overview
Two displays can be selected in the actual signals mode:
• Actual signals display
• Fault memory display
The actual signals display appears first when entering the actual signals
mode. However, when the drive is in a fault condition, the fault memory
display appears instead.
The actual signals display is used to monitor the drive without interfering
with its operation. It continuously displays three selectable actual values.
(1) Display
(2) Actual signal names and values
(3) Selection key for actual
signals mode
(4) Fast navigation key for selecting
the actual signals display or the
fault memory display
(5) Slow navigation key for selecting
signals or fault messages
(6) Enter key for confirming the
selection
1
2
3
4
5
6
1 L ->
600.0 rpm
StateINU
InitSeq....
MOTOR SP
0.00 rpm
POWER